2012•Guangdong Electric PowerRequires access

Analysis on Unbalance of 110 kV Six-circuit Transmission Lines on the Same Tower

Changhui Yang

Open publisher page 2 citations

Abstract

This paper elaborates on three-phase unbalance caused by incomplete transposition of six-circuit transmission lines on the same tower and its influence on safe operation of lines or even the entire power system.By using MATLAB,order parameter and unbalance factor of 110 kV six-circuit transmission lines on the same tower are calculated.On the basis of determined line property,influence of different layouts of phase sequence on unbalance of multi-circuit transmission lines is analyzed.Through comprehensive comparison and analysis,it is concluded that all unbalance factors of six-circuit transmission lines on the same tower are comparatively small in reversed sequence mode and throughtype electromagnetic unbalance factor in particular,hence it is preferentially recommended.

About this research paper

What this paper is about

This paper elaborates on three-phase unbalance caused by incomplete transposition of six-circuit transmission lines on the same tower and its influence on safe operation of lines or even the entire power system.By using MATLAB,order parameter and unbalance factor of 110 kV six-circuit transmission lines on the same tower are calculated.On the basis of determined line property,influence of different layouts of phase sequence on unbalance of multi-circuit transmission lines is analyzed.Through comprehensive comparison and analysis,it is concluded that all unbalance factors of six-circuit transmission lines on the same tower are comparatively small in reversed sequence mode and throughtype electromagnetic unbalance factor in particular,hence it is preferentially recommended.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper elaborates on three-phase unbalance caused by incomplete transposition of six-circuit transmission lines on the same tower and its influence on safe operation of lines or even the entire power system.By using MATLAB,order parameter and unbalance factor of 110 kV six-circuit transmission lines on the same tower are calculated.On the basis of determined line property,influence of different layouts of phase sequence on unbalance of multi-circuit transmission lines is analyzed.Through comprehensive comparison and analysis,it is concluded that all unbalance factors of six-circuit transmission lines on the same tower are comparatively small in reversed sequence mode and throughtype electromagnetic unbalance factor in particular,hence it is preferentially recommended.

Key concepts: Transposition (logic), Tower, Electric power transmission, Engineering, Transmission line, MATLAB, Electrical engineering, Equivalent circuit

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis on Unbalance of 110 kV Six-circuit Transmission Lines on the Same Tower — Research Paper | ScholarLens