2007•Jiangsu Medical JournalRequires access

Intravascular ultrasound-guided drug-eluting stent for treatment of in-stent restenosis

Jinchuan Yan

Open publisher page 0 citations

Abstract

Objective To investigate the efficacy of intravascular ultrasound(IVUS)-guided drug-eluting stent(DES)for the treatment of in-stent restenosis.Methods Fourty-five stent restenosis lesions of 43 consecutive patients with stent restenosis lesions were initially checked by IVUS.The size and length of DES were chosen depending on the results of IVUS.The dilating pressure 13±5atm of DES and post-dilation 15±7atm were decided by the results of IVUS either.Results The IVUS showed that the old stents were not usually completely dilated(38%)and not tightly contacted with the arterial wall(24%).The follow-up of angiography in 29 patients indicated that the re-restenosis in the patients treated by IVUS-guided DES was small(1 case,3.4%).Conclusion The results suggest that IVUS-guided DES is effective for the treatment of in-stent restenosis

About this research paper

What this paper is about

Objective To investigate the efficacy of intravascular ultrasound(IVUS)-guided drug-eluting stent(DES)for the treatment of in-stent restenosis.Methods Fourty-five stent restenosis lesions of 43 consecutive patients with stent restenosis lesions were initially checked by IVUS.The size and length of DES were chosen depending on the results of IVUS.The dilating pressure 13±5atm of DES and post-dilation 15±7atm were decided by the results of IVUS either.Results The IVUS showed that the old stents were not usually completely dilated(38%)and not tightly contacted with the arterial wall(24%).The follow-up of angiography in 29 patients indicated that the re-restenosis in the patients treated by IVUS-guided DES was small(1 case,3.4%).Conclusion The results suggest that IVUS-guided DES is effective for the treatment of in-stent restenosis

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the efficacy of intravascular ultrasound(IVUS)-guided drug-eluting stent(DES)for the treatment of in-stent restenosis.Methods Fourty-five stent restenosis lesions of 43 consecutive patients with stent restenosis lesions were initially checked by IVUS.The size and length of DES were chosen depending on the results of IVUS.The dilating pressure 13±5atm of DES and post-dilation 15±7atm were decided by the results of IVUS either.Results The IVUS showed that the old stents were not usually completely dilated(38%)and not tightly contacted with the arterial wall(24%).The follow-up of angiography in 29 patients indicated that the re-restenosis in the patients treated by IVUS-guided DES was small(1 case,3.4%).Conclusion The results suggest that IVUS-guided DES is effective for the treatment of in-stent restenosis

Key concepts: Restenosis, Intravascular ultrasound, Medicine, Stent, Radiology, Coronary angiography, Angiography, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Intravascular ultrasound-guided drug-eluting stent for treatment of in-stent restenosis — Research Paper | ScholarLens