2008Strait Pharmaceutical JournalRequires access

Determination of ketoconazole in ketoconazole cream by HPLC

Xiaoyan Lin

Open publisher page 0 citations

Abstract

OBJECTIVE To develop an HPLC method for the assay of ketoconazole in its cream.METHODS HPLC was performed on Diamonsil C18 column with methanol-0.02mol·L-1 sodium hydrogen phosphate(70∶30)(pH value was adjusted to 7.0 by diluted phosphoric acid) as mobile phase.The detecting wavelength was 244nm.RESULTS The linear range of ketoconazole was 0.06472~1.618μg(r=0.9999),the average recovery was 101.6%,RSD was 3.43%.CONCLUSION The method is simple,accurate and reproducible.It can be used for quality control of ketoconazole cream.

About this research paper

What this paper is about

OBJECTIVE To develop an HPLC method for the assay of ketoconazole in its cream.METHODS HPLC was performed on Diamonsil C18 column with methanol-0.02mol·L-1 sodium hydrogen phosphate(70∶30)(pH value was adjusted to 7.0 by diluted phosphoric acid) as mobile phase.The detecting wavelength was 244nm.RESULTS The linear range of ketoconazole was 0.06472~1.618μg(r=0.9999),the average recovery was 101.6%,RSD was 3.43%.CONCLUSION The method is simple,accurate and reproducible.It can be used for quality control of ketoconazole cream.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To develop an HPLC method for the assay of ketoconazole in its cream.METHODS HPLC was performed on Diamonsil C18 column with methanol-0.02mol·L-1 sodium hydrogen phosphate(70∶30)(pH value was adjusted to 7.0 by diluted phosphoric acid) as mobile phase.The detecting wavelength was 244nm.RESULTS The linear range of ketoconazole was 0.06472~1.618μg(r=0.9999),the average recovery was 101.6%,RSD was 3.43%.CONCLUSION The method is simple,accurate and reproducible.It can be used for quality control of ketoconazole cream.

Key concepts: Ketoconazole, Phosphoric acid, Chromatography, High-performance liquid chromatography, Chemistry, Methanol, Antifungal, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of ketoconazole in ketoconazole cream by HPLC — Research Paper | ScholarLens