2009Xi'an Jiaotong Daxue xuebaoRequires access

Experimental Comparison Between Ammonia-Water and Ammonia-Water-Lithium Bromide in Absorption Chiller

Haichen Zhao

Open publisher page 1 citations

Abstract

Absorption refrigeration experiment was conducted to find the influences of lithium bromide on the performance of an absorption system with ammonia-water working pair,including variation of vapor-liquid equilibrium property and coefficient of performance(COP) of the system.The relationship between temperature and pressure of the ternary ammonia-water-lithium bromide solution in generation process and COP of the system were determined in the range of 15-80 ℃ and up to 1.5 MPa.Three types of solutions,A(X(NH3)=48%),B(X(NH3)=51.8%,X(LiBr)=42%),and C(X(NH3)=58.7%,X(LiBr)=42%),were adopted in the experiment.The results showed that the generation pressure of the solutions B and C decreased by 21% and 30%,respectively,compared with that of the binary solution with the same NH3 concentration.The pressure reduction increased with the increase of the generation temperature.In addition,the COP of the system with B and C was 0.293 and 0.334,17.2% and 33.6% greater than that with A,respectively.

About this research paper

What this paper is about

Absorption refrigeration experiment was conducted to find the influences of lithium bromide on the performance of an absorption system with ammonia-water working pair,including variation of vapor-liquid equilibrium property and coefficient of performance(COP) of the system.The relationship between temperature and pressure of the ternary ammonia-water-lithium bromide solution in generation process and COP of the system were determined in the range of 15-80 ℃ and up to 1.5 MPa.Three types of solutions,A(X(NH3)=48%),B(X(NH3)=51.8%,X(LiBr)=42%),and C(X(NH3)=58.7%,X(LiBr)=42%),were adopted in the experiment.The results showed that the generation pressure of the solutions B and C decreased by 21% and 30%,respectively,compared with that of the binary solution with the same NH3 concentration.The pressure reduction increased with the increase of the generation temperature.In addition,the COP of the system with B and C was 0.293 and 0.334,17.2% and 33.6% greater than that with A,respectively.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Absorption refrigeration experiment was conducted to find the influences of lithium bromide on the performance of an absorption system with ammonia-water working pair,including variation of vapor-liquid equilibrium property and coefficient of performance(COP) of the system.The relationship between temperature and pressure of the ternary ammonia-water-lithium bromide solution in generation process and COP of the system were determined in the range of 15-80 ℃ and up to 1.5 MPa.Three types of solutions,A(X(NH3)=48%),B(X(NH3)=51.8%,X(LiBr)=42%),and C(X(NH3)=58.7%,X(LiBr)=42%),were adopted in the experiment.The results showed that the generation pressure of the solutions B and C decreased by 21% and 30%,respectively,compared with that of the binary solution with the same NH3 concentration.The pressure reduction increased with the increase of the generation temperature.In addition,the COP of the system with B and C was 0.293 and 0.334,17.2% and 33.6% greater than that with A,respectively.

Key concepts: Lithium bromide, Absorption refrigerator, Ammonia, Coefficient of performance, Chiller, Lithium nitrate, Chemistry, Ternary numeral system