2013•Jisuan lixue xuebaoRequires access

Numerical simulation of thermal fluid in partially open enclosures based on Vreman subgrid-scale model

Huo Yan, Ye Gao

Open publisher page 0 citations

Abstract

Numerical simulations on thermal flow field in a room and two adjoining rooms are carried out by means of the large eddy simulation based on Vreman subgrid-scale model.Results of simulation are evaluated by functional analysis.And results given by Vreman subgrid-scale model are compared with results given by Smagorinsky subgrid-scale mode.It is indicated that two models both give acceptable results in engineering.However,temperature and U velocity calculation results obtained by Vreman subgrid-scale model are closer to experimental values than obtained by Smagorinsky subgrid-scale model in regions near the opening.Vreman subgrid-scale model do not overestimate the coefficient of viscosity for hot gases zone near the wall as Smagorinsky subgrid-scale model do.The accuracy of computation result obtained by Vreman subgrid-scale model is 50%higher than that of Smagorinsky subgrid-scale model for hot smoke layer in a compartment with partially opening.

About this research paper

What this paper is about

Numerical simulations on thermal flow field in a room and two adjoining rooms are carried out by means of the large eddy simulation based on Vreman subgrid-scale model.Results of simulation are evaluated by functional analysis.And results given by Vreman subgrid-scale model are compared with results given by Smagorinsky subgrid-scale mode.It is indicated that two models both give acceptable results in engineering.However,temperature and U velocity calculation results obtained by Vreman subgrid-scale model are closer to experimental values than obtained by Smagorinsky subgrid-scale model in regions near the opening.Vreman subgrid-scale model do not overestimate the coefficient of viscosity for hot gases zone near the wall as Smagorinsky subgrid-scale model do.The accuracy of computation result obtained by Vreman subgrid-scale model is 50%higher than that of Smagorinsky subgrid-scale model for hot smoke layer in a compartment with partially opening.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Numerical simulations on thermal flow field in a room and two adjoining rooms are carried out by means of the large eddy simulation based on Vreman subgrid-scale model.Results of simulation are evaluated by functional analysis.And results given by Vreman subgrid-scale model are compared with results given by Smagorinsky subgrid-scale mode.It is indicated that two models both give acceptable results in engineering.However,temperature and U velocity calculation results obtained by Vreman subgrid-scale model are closer to experimental values than obtained by Smagorinsky subgrid-scale model in regions near the opening.Vreman subgrid-scale model do not overestimate the coefficient of viscosity for hot gases zone near the wall as Smagorinsky subgrid-scale model do.The accuracy of computation result obtained by Vreman subgrid-scale model is 50%higher than that of Smagorinsky subgrid-scale model for hot smoke layer in a compartment with partially opening.

Key concepts: Large eddy simulation, Scale model, Scale (ratio), Mechanics, Computer simulation, Turbulence modeling, Statistical physics, Turbulence

Related papers

Back to paper searchBrowse research topicsOriginal source
Numerical simulation of thermal fluid in partially open enclosures based on Vreman subgrid-scale model — Research Paper | ScholarLens