Optimal Cathodic Protection Potential for X70 Steel with AC Interference Determined by Electrochemical Methods

Shengli Li

Open publisher page 1 citations

Abstract

Electrochemical methods were used to measure the polarization curves of X70 steel under different alternating stray current(AC)voltage conditions and the electrochemical impedance spectroscopy(EIS) under different cathodic polarization potential conditions.The scope of cathodic protection potential and the optimum cathodic protection potential were determined.The results showed that the use of polarization curves and electrochemical impedance spectroscopy could measure the cathodic protection parameters of X70 steel under different AC voltage conditions,and the optimum cathodic protection potential was suggested to be-900 mV(vs.SCE) at the voltage less than 6 V and-1000 mV(vs.SCE) at the voltage greater than 7V.

About this research paper

What this paper is about

Electrochemical methods were used to measure the polarization curves of X70 steel under different alternating stray current(AC)voltage conditions and the electrochemical impedance spectroscopy(EIS) under different cathodic polarization potential conditions.The scope of cathodic protection potential and the optimum cathodic protection potential were determined.The results showed that the use of polarization curves and electrochemical impedance spectroscopy could measure the cathodic protection parameters of X70 steel under different AC voltage conditions,and the optimum cathodic protection potential was suggested to be-900 mV(vs.SCE) at the voltage less than 6 V and-1000 mV(vs.SCE) at the voltage greater than 7V.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electrochemical methods were used to measure the polarization curves of X70 steel under different alternating stray current(AC)voltage conditions and the electrochemical impedance spectroscopy(EIS) under different cathodic polarization potential conditions.The scope of cathodic protection potential and the optimum cathodic protection potential were determined.The results showed that the use of polarization curves and electrochemical impedance spectroscopy could measure the cathodic protection parameters of X70 steel under different AC voltage conditions,and the optimum cathodic protection potential was suggested to be-900 mV(vs.SCE) at the voltage less than 6 V and-1000 mV(vs.SCE) at the voltage greater than 7V.