Rapid Determination of Residual Amounts of Malachite Green and Leuco Malachite Green in Aquatic Products by Ultra-High Performance Liquid Chromatography in Hyphenation with Tandem Mass Spectrometry
Wenkai Chen
Abstract
Wenkai Chen
Abstract
Residual amounts of malachite green(MG) and leuco malachite green(LMG) in aquatic products were determined by ultra-high performance liquid chromatography(UHPLC) hyphenated with tandem mass spectrometry(MS/MS).The compounds,MG and LMG,were extracted from the homogenized tissue sample with acetonitrile in an acetate buffer medium of pH 4.5,separated and purified by liquid-liquid partition and acidic alumina and sodium chloride,as well as acidic alumina and anhydrous sodium sulfate in succession.The clear supernatant liquid after fitration with 0.2 μm filtering membrane was ready for UHPLC-MS/MS analysis.Determinations were performed by using electrospray ionization(ESI+) and multi-reaction monitoring(MRM) modes.Internal standards of D5-MG and D6-LMG were used in the quantification.Under optimized conditions of sample pretreatment and operation of instruments,matrix effect on the MS determination was reduced rationally.Determination(S/N=10) for MG and LMG were found to be 0.19 and 0.10 μg·kg-1 respectively.Tests for recovery were made by addition of standards in the concentration range of 0.5 to 5.0 μg·kg-1,and results obtained were ranged from 89.4% to 110%.Values of RSD′s(n=6) were found in the range of 5.9%-9.8%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Residual amounts of malachite green(MG) and leuco malachite green(LMG) in aquatic products were determined by ultra-high performance liquid chromatography(UHPLC) hyphenated with tandem mass spectrometry(MS/MS).The compounds,MG and LMG,were extracted from the homogenized tissue sample with acetonitrile in an acetate buffer medium of pH 4.5,separated and purified by liquid-liquid partition and acidic alumina and sodium chloride,as well as acidic alumina and anhydrous sodium sulfate in succession.The clear supernatant liquid after fitration with 0.2 μm filtering membrane was ready for UHPLC-MS/MS analysis.Determinations were performed by using electrospray ionization(ESI+) and multi-reaction monitoring(MRM) modes.Internal standards of D5-MG and D6-LMG were used in the quantification.Under optimized conditions of sample pretreatment and operation of instruments,matrix effect on the MS determination was reduced rationally.Determination(S/N=10) for MG and LMG were found to be 0.19 and 0.10 μg·kg-1 respectively.Tests for recovery were made by addition of standards in the concentration range of 0.5 to 5.0 μg·kg-1,and results obtained were ranged from 89.4% to 110%.Values of RSD′s(n=6) were found in the range of 5.9%-9.8%.
Key concepts: Malachite green, Chromatography, Chemistry, Electrospray ionization, Mass spectrometry, Tandem mass spectrometry, Liquid chromatography–mass spectrometry, Detection limit