Study on the determination of vitamin C with sulfosalicylic acid-iron(III) system by spectrophotometry

Yankai Chen

Open publisher page 0 citations

Abstract

Sulfosalicylic acid and Fe(Ⅲ)could form a purple-red complex in a solution with a pH value of 2.00~3.00,and the reducing nature of vitamin C in acid medium could reduce Fe(Ⅲ)to Fe(Ⅱ)in order to reduce the absorbance of the Fe(Ⅲ)-sulfosalicylic system.The absorbance reduction of Fe(Ⅲ)-sulfosalicylic system was in a linear relationship with the contents of vitamin C in a definite range,based on which a new method for the determination of vitamin C was developed.Different variables and parameters affecting the absorbance were studied and optimized.Under the optimum experimental conditions,the linear range of determination was 2.0×10-6~1.2×10-4mol/L,the detection limit was 1.46×10-6 mol/L,and the recoveries were 97.8%~100.4%.The method was simple,accurate and sensitive,and has been used for the determination of vitamin C in orange juice and vegetable samples with satisfactory results.

About this research paper

What this paper is about

Sulfosalicylic acid and Fe(Ⅲ)could form a purple-red complex in a solution with a pH value of 2.00~3.00,and the reducing nature of vitamin C in acid medium could reduce Fe(Ⅲ)to Fe(Ⅱ)in order to reduce the absorbance of the Fe(Ⅲ)-sulfosalicylic system.The absorbance reduction of Fe(Ⅲ)-sulfosalicylic system was in a linear relationship with the contents of vitamin C in a definite range,based on which a new method for the determination of vitamin C was developed.Different variables and parameters affecting the absorbance were studied and optimized.Under the optimum experimental conditions,the linear range of determination was 2.0×10-6~1.2×10-4mol/L,the detection limit was 1.46×10-6 mol/L,and the recoveries were 97.8%~100.4%.The method was simple,accurate and sensitive,and has been used for the determination of vitamin C in orange juice and vegetable samples with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sulfosalicylic acid and Fe(Ⅲ)could form a purple-red complex in a solution with a pH value of 2.00~3.00,and the reducing nature of vitamin C in acid medium could reduce Fe(Ⅲ)to Fe(Ⅱ)in order to reduce the absorbance of the Fe(Ⅲ)-sulfosalicylic system.The absorbance reduction of Fe(Ⅲ)-sulfosalicylic system was in a linear relationship with the contents of vitamin C in a definite range,based on which a new method for the determination of vitamin C was developed.Different variables and parameters affecting the absorbance were studied and optimized.Under the optimum experimental conditions,the linear range of determination was 2.0×10-6~1.2×10-4mol/L,the detection limit was 1.46×10-6 mol/L,and the recoveries were 97.8%~100.4%.The method was simple,accurate and sensitive,and has been used for the determination of vitamin C in orange juice and vegetable samples with satisfactory results.

Key concepts: Sulfosalicylic acid, Chemistry, Absorbance, Spectrophotometry, Detection limit, Chromatography, Linear range, Vitamin C

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the determination of vitamin C with sulfosalicylic acid-iron(III) system by spectrophotometry — Research Paper | ScholarLens