2007Metallurgical AnalysisRequires access

Determination of trace selenium by flow injection-hydride generation-derivative atomic absorption spectrometry

Ha Jing, Kang Wei-jun

Open publisher page 1 citations

Abstract

A flow injection-hydride generation-derivative atomic absorption spectrometry for the determination of selenium is described.Variables such as acidity,reducing agent concen- tration,argon flow rate,reaction coil length,sensitivity grade and other parameters are op- timized.Attention was paid to sensitivity,detection limits,repeatability and determination of selenium in standard substances and in tap water.The results show the proposed method is a simple,accurate and auto method with a detection limit of 0.03 ng/mL.

About this research paper

What this paper is about

A flow injection-hydride generation-derivative atomic absorption spectrometry for the determination of selenium is described.Variables such as acidity,reducing agent concen- tration,argon flow rate,reaction coil length,sensitivity grade and other parameters are op- timized.Attention was paid to sensitivity,detection limits,repeatability and determination of selenium in standard substances and in tap water.The results show the proposed method is a simple,accurate and auto method with a detection limit of 0.03 ng/mL.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A flow injection-hydride generation-derivative atomic absorption spectrometry for the determination of selenium is described.Variables such as acidity,reducing agent concen- tration,argon flow rate,reaction coil length,sensitivity grade and other parameters are op- timized.Attention was paid to sensitivity,detection limits,repeatability and determination of selenium in standard substances and in tap water.The results show the proposed method is a simple,accurate and auto method with a detection limit of 0.03 ng/mL.

Key concepts: Selenium, Hydride, Detection limit, Chemistry, Atomic absorption spectroscopy, Repeatability, Analytical Chemistry (journal), Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace selenium by flow injection-hydride generation-derivative atomic absorption spectrometry — Research Paper | ScholarLens