Application of locking compression plate in treatment of comminuted fracture of distal radius
Yichun Xu
Abstract
Yichun Xu
Abstract
Objective To evaluate the procedure and treatment outcome of AO/ASIF locking compression plate in treatment of comminuted fracture of distal radius. Methods From March 2002 to April 2003, 26 Patients with comminuted fracture of distal radius were operated with locking compression plate. Early and suitable rehabilitation was carried out postoperatively. Results Twenty-two cases were followed-up regularly according to AO evaluation of the wrist joint movement(6-15 months). Bone union occurred in all cases with roentgenographic evidence. The result of comprehensive evaluation was excellent in 11 cases, good in 8 cases, and fair in 3 cases, with 86.3% in excellent and good rate. Conclusion The locking compression plate in treatment of comminuted distal radial fractures can effectively restore and maintain the length of the distal radius after replacement, a good restoration of articular surface, and early restoration of wrist function.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the procedure and treatment outcome of AO/ASIF locking compression plate in treatment of comminuted fracture of distal radius. Methods From March 2002 to April 2003, 26 Patients with comminuted fracture of distal radius were operated with locking compression plate. Early and suitable rehabilitation was carried out postoperatively. Results Twenty-two cases were followed-up regularly according to AO evaluation of the wrist joint movement(6-15 months). Bone union occurred in all cases with roentgenographic evidence. The result of comprehensive evaluation was excellent in 11 cases, good in 8 cases, and fair in 3 cases, with 86.3% in excellent and good rate. Conclusion The locking compression plate in treatment of comminuted distal radial fractures can effectively restore and maintain the length of the distal radius after replacement, a good restoration of articular surface, and early restoration of wrist function.
Key concepts: Medicine, Wrist, Compression (physics), RADIUS, Distal radius fracture, Surgery, Fracture (geology), Radial fractures