2010•Zhongguo huxi yu weizhong jianhu zazhiRequires access

Hemodynamic Monitoring by Pulse-Indicated Continuous Cardiac Output Analysis During Lung Transplantation

Chen Jin-y

Open publisher page 0 citations

Abstract

Objective To explore the hemodynamic monitoring value of pulse-indicated continuous cardiac output(PiCCO)during lung transplantation.Methods Twenty patients with end-stage lung disease undergone lung transplantation were enrolled.Hemodynamic states were monitored by PiCCO and Swan-Ganz standard thermodilution pulmonary artery catheter(PAC)simultaneously at six stages throughout the study.Changes in the variables were calculated by subtracting the first from the second measurement(Δ1)and so on(Δ1 to Δ5).Results The linear correlation between intra-thoracic blood volume index(ITBVI)and stroke volume index(SVIpa)was significant(r=0.654,P0.05),whereas pulmonary artery wedge pressure(PAWP)poorly correlated with SVIpa(P0.05).Changes in ITBVI correlated with changes in SVIpa(Δ1,r=0.621;Δ2,r=0.784;Δ3,r=0.713;Δ4,r=0.740;Δ5,r=0.747;all P0.05),whereas PAWP failed.The mean bias between CIart and CIpa was(0.09±0.5)L·min-1·m-2;the limit of agreement was(-0.89~1.07)L·min-1·m-2.Conclusions There is good correlation between the two methods of PiCCO and PAC for reflecting the change of heart preload.PiCCO is reliable in hemodynamic monitoring in patients undergone lung transplantation.

About this research paper

What this paper is about

Objective To explore the hemodynamic monitoring value of pulse-indicated continuous cardiac output(PiCCO)during lung transplantation.Methods Twenty patients with end-stage lung disease undergone lung transplantation were enrolled.Hemodynamic states were monitored by PiCCO and Swan-Ganz standard thermodilution pulmonary artery catheter(PAC)simultaneously at six stages throughout the study.Changes in the variables were calculated by subtracting the first from the second measurement(Δ1)and so on(Δ1 to Δ5).Results The linear correlation between intra-thoracic blood volume index(ITBVI)and stroke volume index(SVIpa)was significant(r=0.654,P0.05),whereas pulmonary artery wedge pressure(PAWP)poorly correlated with SVIpa(P0.05).Changes in ITBVI correlated with changes in SVIpa(Δ1,r=0.621;Δ2,r=0.784;Δ3,r=0.713;Δ4,r=0.740;Δ5,r=0.747;all P0.05),whereas PAWP failed.The mean bias between CIart and CIpa was(0.09±0.5)L·min-1·m-2;the limit of agreement was(-0.89~1.07)L·min-1·m-2.Conclusions There is good correlation between the two methods of PiCCO and PAC for reflecting the change of heart preload.PiCCO is reliable in hemodynamic monitoring in patients undergone lung transplantation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the hemodynamic monitoring value of pulse-indicated continuous cardiac output(PiCCO)during lung transplantation.Methods Twenty patients with end-stage lung disease undergone lung transplantation were enrolled.Hemodynamic states were monitored by PiCCO and Swan-Ganz standard thermodilution pulmonary artery catheter(PAC)simultaneously at six stages throughout the study.Changes in the variables were calculated by subtracting the first from the second measurement(Δ1)and so on(Δ1 to Δ5).Results The linear correlation between intra-thoracic blood volume index(ITBVI)and stroke volume index(SVIpa)was significant(r=0.654,P0.05),whereas pulmonary artery wedge pressure(PAWP)poorly correlated with SVIpa(P0.05).Changes in ITBVI correlated with changes in SVIpa(Δ1,r=0.621;Δ2,r=0.784;Δ3,r=0.713;Δ4,r=0.740;Δ5,r=0.747;all P0.05),whereas PAWP failed.The mean bias between CIart and CIpa was(0.09±0.5)L·min-1·m-2;the limit of agreement was(-0.89~1.07)L·min-1·m-2.Conclusions There is good correlation between the two methods of PiCCO and PAC for reflecting the change of heart preload.PiCCO is reliable in hemodynamic monitoring in patients undergone lung transplantation.

Key concepts: Medicine, Cardiac output, Preload, Pulmonary artery catheter, Hemodynamics, Cardiac index, Pulmonary wedge pressure, Pulmonary artery

Related papers

Back to paper searchBrowse research topicsOriginal source
Hemodynamic Monitoring by Pulse-Indicated Continuous Cardiac Output Analysis During Lung Transplantation — Research Paper | ScholarLens