2005Advanced Technology of Electrical Engineering and EnergyRequires access

Measurement and Suppression of Common-mode and Differential-mode EMI in PWM Converter System

Xue Wen-yan

Open publisher page 0 citations

Abstract

This paper discusses how to reduce conducted electromagnetic interference (EMI) in an AC/DC converter system to accord with EN class A. Herein some passive methods of suppressing conducted EMI noise, such as mixed-mode (MM) EMI filters, snubbing circuits, are used. Based on measurement, the sources of noise are detected with characteristics analyzed in detail. The MM EMI filter is valuable means with which the conducted EMI noise can be effectively reduced. A simple method of designing EMI filter, combining theoretical calculation with practical modification, is presented. It is easily implemented with only the amplitude of noise and sink impedances required. The experiment results prove that the methods adopted are viable and effective.

About this research paper

What this paper is about

This paper discusses how to reduce conducted electromagnetic interference (EMI) in an AC/DC converter system to accord with EN class A. Herein some passive methods of suppressing conducted EMI noise, such as mixed-mode (MM) EMI filters, snubbing circuits, are used. Based on measurement, the sources of noise are detected with characteristics analyzed in detail. The MM EMI filter is valuable means with which the conducted EMI noise can be effectively reduced. A simple method of designing EMI filter, combining theoretical calculation with practical modification, is presented. It is easily implemented with only the amplitude of noise and sink impedances required. The experiment results prove that the methods adopted are viable and effective.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper discusses how to reduce conducted electromagnetic interference (EMI) in an AC/DC converter system to accord with EN class A. Herein some passive methods of suppressing conducted EMI noise, such as mixed-mode (MM) EMI filters, snubbing circuits, are used. Based on measurement, the sources of noise are detected with characteristics analyzed in detail. The MM EMI filter is valuable means with which the conducted EMI noise can be effectively reduced. A simple method of designing EMI filter, combining theoretical calculation with practical modification, is presented. It is easily implemented with only the amplitude of noise and sink impedances required. The experiment results prove that the methods adopted are viable and effective.

Key concepts: EMI, Electromagnetic interference, Conducted electromagnetic interference, Common-mode signal, Electronic engineering, Noise (video), Filter (signal processing), Electromagnetic compatibility

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement and Suppression of Common-mode and Differential-mode EMI in PWM Converter System — Research Paper | ScholarLens