2011Journal of Henan Polytechnic UniversityRequires access

Determination of trace cadmium in water samples tested by graphite furnace atomic absorption spectrographic method

Hong‐Yan Bie

Open publisher page 0 citations

Abstract

A new method for the determination of cadmium(Cd) in water samples tested by graphite furnace atomic absorption spectrometry(GFAAS) was developed.Ashing temperature and time,atomization temperature and time,the effect of potential interference of coexisting ions on the determination of Cd were investigated in detail.Under the optimized conditions,the limit of detection(LOD) for Cd was 0.13 ng/mL,the precision relative standard deviation(RSD) for seven replicate measurements of 2.0 ng/mL Cd was 3.1%,and the calibration curve was obtained with a series of Cd standard solutions ranged in 0 ~ 10 ng/mL.The developed method was applied to the determination of Cd in water samples and the recoveries for the spiked samples were in the range of 94.9%~ 107.5%.For validation,the developed method was also applied to the determination of Cd in a certified reference material of GBW08608 and the determined value was in good agreement with the certified one.

About this research paper

What this paper is about

A new method for the determination of cadmium(Cd) in water samples tested by graphite furnace atomic absorption spectrometry(GFAAS) was developed.Ashing temperature and time,atomization temperature and time,the effect of potential interference of coexisting ions on the determination of Cd were investigated in detail.Under the optimized conditions,the limit of detection(LOD) for Cd was 0.13 ng/mL,the precision relative standard deviation(RSD) for seven replicate measurements of 2.0 ng/mL Cd was 3.1%,and the calibration curve was obtained with a series of Cd standard solutions ranged in 0 ~ 10 ng/mL.The developed method was applied to the determination of Cd in water samples and the recoveries for the spiked samples were in the range of 94.9%~ 107.5%.For validation,the developed method was also applied to the determination of Cd in a certified reference material of GBW08608 and the determined value was in good agreement with the certified one.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for the determination of cadmium(Cd) in water samples tested by graphite furnace atomic absorption spectrometry(GFAAS) was developed.Ashing temperature and time,atomization temperature and time,the effect of potential interference of coexisting ions on the determination of Cd were investigated in detail.Under the optimized conditions,the limit of detection(LOD) for Cd was 0.13 ng/mL,the precision relative standard deviation(RSD) for seven replicate measurements of 2.0 ng/mL Cd was 3.1%,and the calibration curve was obtained with a series of Cd standard solutions ranged in 0 ~ 10 ng/mL.The developed method was applied to the determination of Cd in water samples and the recoveries for the spiked samples were in the range of 94.9%~ 107.5%.For validation,the developed method was also applied to the determination of Cd in a certified reference material of GBW08608 and the determined value was in good agreement with the certified one.

Key concepts: Ashing, Graphite furnace atomic absorption, Detection limit, Certified reference materials, Cadmium, Analytical Chemistry (journal), Calibration curve, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace cadmium in water samples tested by graphite furnace atomic absorption spectrographic method — Research Paper | ScholarLens