Survey on the Status of Indoor Air Formaldehyde Contamination among Residential Apartments in Liyang City,2008-2009

HU Yun-qin

Open publisher page 1 citations

Abstract

[Objective] To study the status of indoor air formaldehyde contamination among residential apartments after decoration and the law of change.[Methods]From March 2008 to June 2009,10 newly decorated residential apartments were sampled in Liyang city to conduct indoor air formaldehyde concentration test for 12 consecutive months.[Results]The average indoor air formaldehyde concentration(mg/m3) in 10 residential apartments was 0.004 before decoration,and 0.196,0.200,0.155,0.115,0.089,0.078,and 0.072,respectively on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months,with statistical difference in formaldehyde concentration testing(P0.05);the passing rate of formaldehyde was 5.00%,12.50%,32.50%,52.50%,72.50%,90.00%,and 95.00%(P0.01) on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months.The passing rate of indoor air formaldehyde concentration was 50.00%,48.71%,42.86%,and 58.57% respectively(P0.05) for the living room,bedroom,study,kitchen.[Conclusion]The average indoor air formaldehyde concentration in Liyang city reach the indoor air quality standards requirements,and the formaldehyde concentration is decreasing with time.

About this research paper

What this paper is about

[Objective] To study the status of indoor air formaldehyde contamination among residential apartments after decoration and the law of change.[Methods]From March 2008 to June 2009,10 newly decorated residential apartments were sampled in Liyang city to conduct indoor air formaldehyde concentration test for 12 consecutive months.[Results]The average indoor air formaldehyde concentration(mg/m3) in 10 residential apartments was 0.004 before decoration,and 0.196,0.200,0.155,0.115,0.089,0.078,and 0.072,respectively on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months,with statistical difference in formaldehyde concentration testing(P0.05);the passing rate of formaldehyde was 5.00%,12.50%,32.50%,52.50%,72.50%,90.00%,and 95.00%(P0.01) on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months.The passing rate of indoor air formaldehyde concentration was 50.00%,48.71%,42.86%,and 58.57% respectively(P0.05) for the living room,bedroom,study,kitchen.[Conclusion]The average indoor air formaldehyde concentration in Liyang city reach the indoor air quality standards requirements,and the formaldehyde concentration is decreasing with time.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] To study the status of indoor air formaldehyde contamination among residential apartments after decoration and the law of change.[Methods]From March 2008 to June 2009,10 newly decorated residential apartments were sampled in Liyang city to conduct indoor air formaldehyde concentration test for 12 consecutive months.[Results]The average indoor air formaldehyde concentration(mg/m3) in 10 residential apartments was 0.004 before decoration,and 0.196,0.200,0.155,0.115,0.089,0.078,and 0.072,respectively on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months,with statistical difference in formaldehyde concentration testing(P0.05);the passing rate of formaldehyde was 5.00%,12.50%,32.50%,52.50%,72.50%,90.00%,and 95.00%(P0.01) on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months.The passing rate of indoor air formaldehyde concentration was 50.00%,48.71%,42.86%,and 58.57% respectively(P0.05) for the living room,bedroom,study,kitchen.[Conclusion]The average indoor air formaldehyde concentration in Liyang city reach the indoor air quality standards requirements,and the formaldehyde concentration is decreasing with time.

Key concepts: Bedroom, Formaldehyde, Indoor air, Indoor air quality, Living room, Environmental science, Significant difference, Contamination