Survey on the Status of Indoor Air Formaldehyde Contamination among Residential Apartments in Liyang City,2008-2009
HU Yun-qin
Abstract
HU Yun-qin
Abstract
[Objective] To study the status of indoor air formaldehyde contamination among residential apartments after decoration and the law of change.[Methods]From March 2008 to June 2009,10 newly decorated residential apartments were sampled in Liyang city to conduct indoor air formaldehyde concentration test for 12 consecutive months.[Results]The average indoor air formaldehyde concentration(mg/m3) in 10 residential apartments was 0.004 before decoration,and 0.196,0.200,0.155,0.115,0.089,0.078,and 0.072,respectively on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months,with statistical difference in formaldehyde concentration testing(P0.05);the passing rate of formaldehyde was 5.00%,12.50%,32.50%,52.50%,72.50%,90.00%,and 95.00%(P0.01) on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months.The passing rate of indoor air formaldehyde concentration was 50.00%,48.71%,42.86%,and 58.57% respectively(P0.05) for the living room,bedroom,study,kitchen.[Conclusion]The average indoor air formaldehyde concentration in Liyang city reach the indoor air quality standards requirements,and the formaldehyde concentration is decreasing with time.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
[Objective] To study the status of indoor air formaldehyde contamination among residential apartments after decoration and the law of change.[Methods]From March 2008 to June 2009,10 newly decorated residential apartments were sampled in Liyang city to conduct indoor air formaldehyde concentration test for 12 consecutive months.[Results]The average indoor air formaldehyde concentration(mg/m3) in 10 residential apartments was 0.004 before decoration,and 0.196,0.200,0.155,0.115,0.089,0.078,and 0.072,respectively on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months,with statistical difference in formaldehyde concentration testing(P0.05);the passing rate of formaldehyde was 5.00%,12.50%,32.50%,52.50%,72.50%,90.00%,and 95.00%(P0.01) on the day upon completion,2 months after completion,4 months,6 months,8 months,10 months,12 months.The passing rate of indoor air formaldehyde concentration was 50.00%,48.71%,42.86%,and 58.57% respectively(P0.05) for the living room,bedroom,study,kitchen.[Conclusion]The average indoor air formaldehyde concentration in Liyang city reach the indoor air quality standards requirements,and the formaldehyde concentration is decreasing with time.
Key concepts: Bedroom, Formaldehyde, Indoor air, Indoor air quality, Living room, Environmental science, Significant difference, Contamination