2012•Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of Zn in Tap-Water by Hydride Generation-Atomic Fluorescence Spectrometry

Bai Hui

Open publisher page 0 citations

Abstract

The suitable measurement conditions for the determination of trace zinc in tap-water by hydride generation-atomic fluorescence spectrometry(HG-AFS) were studied,focusing on optimizing conditions of instruments and reagents,and the effect of zinc signal reinforcer on the determination was inspected.The results showed that under the optimized conditions,the fluorescence intensity was large and stable.The linear range was 0—250μg·L-1 with r=0.9898,the detection limit was 0.55μg·L-1 and the recovery was 82.53%—104.6% with RSD of 3.2%—7.0%.The method was applied to determining zinc in water with satisfactory result.

About this research paper

What this paper is about

The suitable measurement conditions for the determination of trace zinc in tap-water by hydride generation-atomic fluorescence spectrometry(HG-AFS) were studied,focusing on optimizing conditions of instruments and reagents,and the effect of zinc signal reinforcer on the determination was inspected.The results showed that under the optimized conditions,the fluorescence intensity was large and stable.The linear range was 0—250μg·L-1 with r=0.9898,the detection limit was 0.55μg·L-1 and the recovery was 82.53%—104.6% with RSD of 3.2%—7.0%.The method was applied to determining zinc in water with satisfactory result.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The suitable measurement conditions for the determination of trace zinc in tap-water by hydride generation-atomic fluorescence spectrometry(HG-AFS) were studied,focusing on optimizing conditions of instruments and reagents,and the effect of zinc signal reinforcer on the determination was inspected.The results showed that under the optimized conditions,the fluorescence intensity was large and stable.The linear range was 0—250μg·L-1 with r=0.9898,the detection limit was 0.55μg·L-1 and the recovery was 82.53%—104.6% with RSD of 3.2%—7.0%.The method was applied to determining zinc in water with satisfactory result.

Key concepts: Tap water, Detection limit, Hydride, Zinc, Linear range, Chemistry, Reagent, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Zn in Tap-Water by Hydride Generation-Atomic Fluorescence Spectrometry — Research Paper | ScholarLens