2010•PubMedRequires access

[Simultaneous detection of measles and rubella virus by multiplex real-time RT-PCR with an internal control].

Bei-bei Yu, Yan Feng, Changping Xu, Yi-yu Lu, Jing Qian

Open publisher page 1 citations

Abstract

Measles and rubella virus cause fever rash diseases that are uneasy to differentiate clinically from each other. Specific primers and fluorescence-labeled probes were designed, and a multiplex Real-time RT-PCR with an internal control was developed to simultaneously identify the measles and rubella virus. The multiplex Real-time RT-PCR assay was specific and no false positive or false negative results were found. The sensitivity of the assay was 0.1TCID50/mL and 1TCID50/mL for measles and rubella virus respectively. Analysis with 0.1-10(3)TCID50/mL measles or rubella virus samples demonstrated high validity and reproducibility with the coefficient of variability(CV) of below 0.9% for both measles and rubella virus. Using ribonuclease P (RNase P) as internal false negative control, the developed multiplex Real-time RT-PCR assay is suitable for rapid clinical diagnosis of measles and rubella virus.

About this research paper

What this paper is about

Measles and rubella virus cause fever rash diseases that are uneasy to differentiate clinically from each other. Specific primers and fluorescence-labeled probes were designed, and a multiplex Real-time RT-PCR with an internal control was developed to simultaneously identify the measles and rubella virus. The multiplex Real-time RT-PCR assay was specific and no false positive or false negative results were found. The sensitivity of the assay was 0.1TCID50/mL and 1TCID50/mL for measles and rubella virus respectively. Analysis with 0.1-10(3)TCID50/mL measles or rubella virus samples demonstrated high validity and reproducibility with the coefficient of variability(CV) of below 0.9% for both measles and rubella virus. Using ribonuclease P (RNase P) as internal false negative control, the developed multiplex Real-time RT-PCR assay is suitable for rapid clinical diagnosis of measles and rubella virus.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Measles and rubella virus cause fever rash diseases that are uneasy to differentiate clinically from each other. Specific primers and fluorescence-labeled probes were designed, and a multiplex Real-time RT-PCR with an internal control was developed to simultaneously identify the measles and rubella virus. The multiplex Real-time RT-PCR assay was specific and no false positive or false negative results were found. The sensitivity of the assay was 0.1TCID50/mL and 1TCID50/mL for measles and rubella virus respectively. Analysis with 0.1-10(3)TCID50/mL measles or rubella virus samples demonstrated high validity and reproducibility with the coefficient of variability(CV) of below 0.9% for both measles and rubella virus. Using ribonuclease P (RNase P) as internal false negative control, the developed multiplex Real-time RT-PCR assay is suitable for rapid clinical diagnosis of measles and rubella virus.

Key concepts: Rubella, Measles, Rubella virus, Measles virus, Virology, Multiplex, Real-time polymerase chain reaction, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Simultaneous detection of measles and rubella virus by multiplex real-time RT-PCR with an internal control]. — Research Paper | ScholarLens