[Simultaneous detection of measles and rubella virus by multiplex real-time RT-PCR with an internal control].
Bei-bei Yu, Yan Feng, Changping Xu, Yi-yu Lu, Jing Qian
Abstract
Bei-bei Yu, Yan Feng, Changping Xu, Yi-yu Lu, Jing Qian
Abstract
Measles and rubella virus cause fever rash diseases that are uneasy to differentiate clinically from each other. Specific primers and fluorescence-labeled probes were designed, and a multiplex Real-time RT-PCR with an internal control was developed to simultaneously identify the measles and rubella virus. The multiplex Real-time RT-PCR assay was specific and no false positive or false negative results were found. The sensitivity of the assay was 0.1TCID50/mL and 1TCID50/mL for measles and rubella virus respectively. Analysis with 0.1-10(3)TCID50/mL measles or rubella virus samples demonstrated high validity and reproducibility with the coefficient of variability(CV) of below 0.9% for both measles and rubella virus. Using ribonuclease P (RNase P) as internal false negative control, the developed multiplex Real-time RT-PCR assay is suitable for rapid clinical diagnosis of measles and rubella virus.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Measles and rubella virus cause fever rash diseases that are uneasy to differentiate clinically from each other. Specific primers and fluorescence-labeled probes were designed, and a multiplex Real-time RT-PCR with an internal control was developed to simultaneously identify the measles and rubella virus. The multiplex Real-time RT-PCR assay was specific and no false positive or false negative results were found. The sensitivity of the assay was 0.1TCID50/mL and 1TCID50/mL for measles and rubella virus respectively. Analysis with 0.1-10(3)TCID50/mL measles or rubella virus samples demonstrated high validity and reproducibility with the coefficient of variability(CV) of below 0.9% for both measles and rubella virus. Using ribonuclease P (RNase P) as internal false negative control, the developed multiplex Real-time RT-PCR assay is suitable for rapid clinical diagnosis of measles and rubella virus.
Key concepts: Rubella, Measles, Rubella virus, Measles virus, Virology, Multiplex, Real-time polymerase chain reaction, Biology