Application of Cuffed Catheter in Right Internal Jugular Vein in Hemodialysis
Deng Yan-yan
Abstract
Deng Yan-yan
Abstract
Objective To investigate the value of cuffed catheter indwelling in right internal jugular vein in maintenance of hemodialysis.Methods Forty-one cases were implanted dual-lumen cuffed catheters in right jugular vein as vascular access,and the clinical efficacy and complications were observed.Results ⑴The indwelling time of the catheters were(14.3±10.5)months,the blood flow was from 200 mL/min to 300 mL/min;⑵The endpoint of catheters was 12 case-times,the using time of catheters were(8.2±6.1)months at the endpoint;⑶The incidence of hemorrhage or haematoma was 43.9%,the rate of catheter malposition was 2.4%;⑷The average incidence of the catheter related infection was 0.586 per 100 catheters days and the incidence of catheter thrombosis was 31.7%;⑸The decline rate of urea was(71.5±0.06)% and the KT/V(urea)was 1.42±0.19 in 41 cuffed catheter cases.Conclusion Cuffed catheter in right internal jugular vein is a safe and effective vascular access in maintenance of hemodialysis.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To investigate the value of cuffed catheter indwelling in right internal jugular vein in maintenance of hemodialysis.Methods Forty-one cases were implanted dual-lumen cuffed catheters in right jugular vein as vascular access,and the clinical efficacy and complications were observed.Results ⑴The indwelling time of the catheters were(14.3±10.5)months,the blood flow was from 200 mL/min to 300 mL/min;⑵The endpoint of catheters was 12 case-times,the using time of catheters were(8.2±6.1)months at the endpoint;⑶The incidence of hemorrhage or haematoma was 43.9%,the rate of catheter malposition was 2.4%;⑷The average incidence of the catheter related infection was 0.586 per 100 catheters days and the incidence of catheter thrombosis was 31.7%;⑸The decline rate of urea was(71.5±0.06)% and the KT/V(urea)was 1.42±0.19 in 41 cuffed catheter cases.Conclusion Cuffed catheter in right internal jugular vein is a safe and effective vascular access in maintenance of hemodialysis.
Key concepts: Medicine, Catheter, Hemodialysis, Hemodialysis Catheter, Surgery, Internal jugular vein, Jugular vein, Lumen (anatomy)