Improving operation speed of differential protection for transformer at serious interior fault

Yang Hui-hong

Open publisher page 0 citations

Abstract

By analyzing the cause of operation time of differential protection and the problem of over-current protection in application,a solution is proposed by adding the fast operation zone to improve the operation speed of transformer differential protection according to the relationship between differential current and restraint current.The numerical simulation results verify that this solution can effectively shorten the operation time of differential protection while the serious internal faults occurring.

About this research paper

What this paper is about

By analyzing the cause of operation time of differential protection and the problem of over-current protection in application,a solution is proposed by adding the fast operation zone to improve the operation speed of transformer differential protection according to the relationship between differential current and restraint current.The numerical simulation results verify that this solution can effectively shorten the operation time of differential protection while the serious internal faults occurring.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

By analyzing the cause of operation time of differential protection and the problem of over-current protection in application,a solution is proposed by adding the fast operation zone to improve the operation speed of transformer differential protection according to the relationship between differential current and restraint current.The numerical simulation results verify that this solution can effectively shorten the operation time of differential protection while the serious internal faults occurring.

Key concepts: Differential protection, Transformer, Current transformer, Differential (mechanical device), Current (fluid), Control theory (sociology), Computer science, Engineering