Studies on the Overvoltage for Eliminating 750 kV Circuit Breaker Pre-inset Resistor
SU Yu-ping
Abstract
SU Yu-ping
Abstract
Eliminating pre-inset resistor of 750 kV circuit breaker can save costs and increase operation stability.A arresters were installed at both ends of 750 kV high voltage transmission line to suppress switching overvoltage.The effects of the number and positions of arrestor on the 750 kV Lanzhoudong-Yinchuandong transmission line on the switching over voltages,including three phases energizing line without load and single phase auto-reclosing,were analyzed using the electromagnetic transient program(ATP-EMTP).The results show that without any arresters,the maximum overvoltage while three phase energizing line with no load is 2.38 p.u.and for single auto-reclosing is 2.57 p.u.when the line is shorter and the install surge arresters at both ends,the ways can operate the above-mentioned two types of statistical overvoltage suppression to below 1.80,it can be seen when the abolition of the short circuit switch resistance is possible.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Eliminating pre-inset resistor of 750 kV circuit breaker can save costs and increase operation stability.A arresters were installed at both ends of 750 kV high voltage transmission line to suppress switching overvoltage.The effects of the number and positions of arrestor on the 750 kV Lanzhoudong-Yinchuandong transmission line on the switching over voltages,including three phases energizing line without load and single phase auto-reclosing,were analyzed using the electromagnetic transient program(ATP-EMTP).The results show that without any arresters,the maximum overvoltage while three phase energizing line with no load is 2.38 p.u.and for single auto-reclosing is 2.57 p.u.when the line is shorter and the install surge arresters at both ends,the ways can operate the above-mentioned two types of statistical overvoltage suppression to below 1.80,it can be seen when the abolition of the short circuit switch resistance is possible.
Key concepts: Overvoltage, Circuit breaker, Electrical engineering, Resistor, Surge arrester, Lightning arrester, Sulfur hexafluoride circuit breaker, Transmission line