2011•Physical Testing and Chemical AnalysisRequires access

FAAS Determination of Magnesium in RE-Mg-Si-Fe Alloy

Qianghua Wu

Open publisher page 0 citations

Abstract

Sample of RE-Mg-Si-Fe alloy was dissolved with con.HF and con.HNO3,and Mg2+ in the solution was determined by FAAS.La(Ⅲ) solution as releasing agent was added to eliminate the interferences of coexisting ions.Linear relationship between values of absorbance and mass concentration of Mg2+ was kept in the range of 0.2-12.0 mg·L-1,and detection limit(3s) of the method found was 0.057 mg L-1.The proposed method was applied to the analysis of two samples,giving values of recovery found by standard addition method of 99.4% and 97.6%,and RSD′s(n=11) of 0.89% and 0.43% respectively.

About this research paper

What this paper is about

Sample of RE-Mg-Si-Fe alloy was dissolved with con.HF and con.HNO3,and Mg2+ in the solution was determined by FAAS.La(Ⅲ) solution as releasing agent was added to eliminate the interferences of coexisting ions.Linear relationship between values of absorbance and mass concentration of Mg2+ was kept in the range of 0.2-12.0 mg·L-1,and detection limit(3s) of the method found was 0.057 mg L-1.The proposed method was applied to the analysis of two samples,giving values of recovery found by standard addition method of 99.4% and 97.6%,and RSD′s(n=11) of 0.89% and 0.43% respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sample of RE-Mg-Si-Fe alloy was dissolved with con.HF and con.HNO3,and Mg2+ in the solution was determined by FAAS.La(Ⅲ) solution as releasing agent was added to eliminate the interferences of coexisting ions.Linear relationship between values of absorbance and mass concentration of Mg2+ was kept in the range of 0.2-12.0 mg·L-1,and detection limit(3s) of the method found was 0.057 mg L-1.The proposed method was applied to the analysis of two samples,giving values of recovery found by standard addition method of 99.4% and 97.6%,and RSD′s(n=11) of 0.89% and 0.43% respectively.

Key concepts: Absorbance, Detection limit, Alloy, Magnesium, Analytical Chemistry (journal), Chemistry, Ion, Standard addition

Related papers

Back to paper searchBrowse research topicsOriginal source
FAAS Determination of Magnesium in RE-Mg-Si-Fe Alloy — Research Paper | ScholarLens