Analysis of failure protection output the other sides of the transformer and open voltage block on transformer unit

Shaoliang Chen

Open full text 0 citations

Abstract

Busbar protection and transformer protection is main element protection in substation. In tradition,the protection zone is specific limit,is nothing cooperation problem between busbar protection equipment and transformer protection equipment. But according to development power grid in China,it brings up the problem failure protection output the other sides of the transformer and open voltage block on transformer unit. This paper analyzes these problems and provides a solution,which can be used as a reference to personnel of electric power project and technique standard.

About this research paper

What this paper is about

Busbar protection and transformer protection is main element protection in substation. In tradition,the protection zone is specific limit,is nothing cooperation problem between busbar protection equipment and transformer protection equipment. But according to development power grid in China,it brings up the problem failure protection output the other sides of the transformer and open voltage block on transformer unit. This paper analyzes these problems and provides a solution,which can be used as a reference to personnel of electric power project and technique standard.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Busbar protection and transformer protection is main element protection in substation. In tradition,the protection zone is specific limit,is nothing cooperation problem between busbar protection equipment and transformer protection equipment. But according to development power grid in China,it brings up the problem failure protection output the other sides of the transformer and open voltage block on transformer unit. This paper analyzes these problems and provides a solution,which can be used as a reference to personnel of electric power project and technique standard.

Key concepts: Busbar, Engineering, Transformer, Current transformer, Electrical engineering, Delta-wye transformer, Distribution transformer, Isolation transformer

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of failure protection output the other sides of the transformer and open voltage block on transformer unit — Research Paper | ScholarLens