2013Journal of Henan UniversityRequires access

Removal of Ammonia Nitrogen in ADC Condensation Wastewater by Ultrasound Stripping

Deliang Li

Open publisher page 0 citations

Abstract

ADC foaming agent condensation water belongs to high concentration ammonia nitrogen wastewater and particularly contains a large amount of refractory material and biological organisms toxic substances.According to this characteristic,experiments of removal of ammonia nitrogen from wastewater by stripping were carried out,influencing factors on the removal rate of ammonia-nitrogen including pH value,temperature,air flow rate and aeration gas were investigated.On this basis,the application of ultrasound to wastewater treatment was studied.The results indicated that the removal rate of ammonia nitrogen reached 92% under the optimal conditions as pH 10,temperature 30 ℃,air flow rate 1.0 L·min-1,ultrasonic power 400 W and ultrasound stripping times of 180 min.

About this research paper

What this paper is about

ADC foaming agent condensation water belongs to high concentration ammonia nitrogen wastewater and particularly contains a large amount of refractory material and biological organisms toxic substances.According to this characteristic,experiments of removal of ammonia nitrogen from wastewater by stripping were carried out,influencing factors on the removal rate of ammonia-nitrogen including pH value,temperature,air flow rate and aeration gas were investigated.On this basis,the application of ultrasound to wastewater treatment was studied.The results indicated that the removal rate of ammonia nitrogen reached 92% under the optimal conditions as pH 10,temperature 30 ℃,air flow rate 1.0 L·min-1,ultrasonic power 400 W and ultrasound stripping times of 180 min.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ADC foaming agent condensation water belongs to high concentration ammonia nitrogen wastewater and particularly contains a large amount of refractory material and biological organisms toxic substances.According to this characteristic,experiments of removal of ammonia nitrogen from wastewater by stripping were carried out,influencing factors on the removal rate of ammonia-nitrogen including pH value,temperature,air flow rate and aeration gas were investigated.On this basis,the application of ultrasound to wastewater treatment was studied.The results indicated that the removal rate of ammonia nitrogen reached 92% under the optimal conditions as pH 10,temperature 30 ℃,air flow rate 1.0 L·min-1,ultrasonic power 400 W and ultrasound stripping times of 180 min.

Key concepts: Stripping (fiber), Ammonia, Wastewater, Chemistry, Nitrogen, Aeration, Air stripping, Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Removal of Ammonia Nitrogen in ADC Condensation Wastewater by Ultrasound Stripping — Research Paper | ScholarLens