2011Journal of Hefei UniversityRequires access

Study of Carbon Monoxide Concentrations' Detection Based on TDLAS

Yang Te-yu

Open publisher page 0 citations

Abstract

Tunable diode laser absorption spectroscopy(TDLAS) is make use of absorption spectroscopy of gas molecules,it is a new method of trace gas composition and the concentration of atmospheric pollution.Introduced the construct and principle of TDLAS system,analyzed the detection theory of second harmonic signal of gas,established of the model between second harmonic signal of concentrations to be tested and the second harmonic signals of standard gas concentration,the model's accuracy proved to be highly by experiment.

About this research paper

What this paper is about

Tunable diode laser absorption spectroscopy(TDLAS) is make use of absorption spectroscopy of gas molecules,it is a new method of trace gas composition and the concentration of atmospheric pollution.Introduced the construct and principle of TDLAS system,analyzed the detection theory of second harmonic signal of gas,established of the model between second harmonic signal of concentrations to be tested and the second harmonic signals of standard gas concentration,the model's accuracy proved to be highly by experiment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Tunable diode laser absorption spectroscopy(TDLAS) is make use of absorption spectroscopy of gas molecules,it is a new method of trace gas composition and the concentration of atmospheric pollution.Introduced the construct and principle of TDLAS system,analyzed the detection theory of second harmonic signal of gas,established of the model between second harmonic signal of concentrations to be tested and the second harmonic signals of standard gas concentration,the model's accuracy proved to be highly by experiment.

Key concepts: Tunable diode laser absorption spectroscopy, Harmonic, Absorption (acoustics), SIGNAL (programming language), Carbon monoxide, Spectroscopy, Absorption spectroscopy, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of Carbon Monoxide Concentrations' Detection Based on TDLAS — Research Paper | ScholarLens