Spectrophotometric determination of trace cadmium with cadmium(II)-o-phenanthroline-eosin Y complex system
Zhao Sheng-ping
Abstract
Zhao Sheng-ping
Abstract
The color reaction conditions of cadmium with o-phenanthroline and eosin Y(EY) was investigated.The results showed that cadmium could react with o-phenanthroline and EY to form a stable ion complex [Cd(phen)3]EY which had maximum absorption peak at 568 nm in HAc-NaAc buffer solution at pH 5.0.Beer's law was obeyed in the concentration range of 0.02-0.8 μg/mL for cadmium.The apparent molar absorptivity was 1.07×105 L·mol-1·cm-1 and the detection limit was 11.69 μg/L.Most common irons did not interfere with the determination.The interference of high-content Ag+,Hg2+ and Ni2+ was serious and they should be separated and removed with sulphydryl cotton before determination.The proposed method has been applied to the determination of cadmium in industrial wastewater samples,and the results were consistent with those obtained by atomic absorption spectrometry.The relative standard deviations(RSD,n=5) were 1.3%-1.6 %,and the recoveries were 98%-103%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The color reaction conditions of cadmium with o-phenanthroline and eosin Y(EY) was investigated.The results showed that cadmium could react with o-phenanthroline and EY to form a stable ion complex [Cd(phen)3]EY which had maximum absorption peak at 568 nm in HAc-NaAc buffer solution at pH 5.0.Beer's law was obeyed in the concentration range of 0.02-0.8 μg/mL for cadmium.The apparent molar absorptivity was 1.07×105 L·mol-1·cm-1 and the detection limit was 11.69 μg/L.Most common irons did not interfere with the determination.The interference of high-content Ag+,Hg2+ and Ni2+ was serious and they should be separated and removed with sulphydryl cotton before determination.The proposed method has been applied to the determination of cadmium in industrial wastewater samples,and the results were consistent with those obtained by atomic absorption spectrometry.The relative standard deviations(RSD,n=5) were 1.3%-1.6 %,and the recoveries were 98%-103%.
Key concepts: Cadmium, Molar absorptivity, Chemistry, Phenanthroline, Eosin Y, Detection limit, Buffer solution, Eosin