[Revealing mechanical property of intact rabbit tibia in three-point bending test].
Honggang Zhong, Weihua Liu, Hai-bin Bu, Qian Min-quan
Abstract
Honggang Zhong, Weihua Liu, Hai-bin Bu, Qian Min-quan
Abstract
OBJECTIVE: To explore the mechanical property of intact long bone through three-point bending test of rabbit tibia according to mechanics of materials. METHODS: Ten pairs of normal rabbits tibia were treated on three-point bending test with 80 mm supporting distance in order to corroborate the virtual loading test on bone model. RESULTS: Bending stiffness and strength of 10 pairs of normal rabbit tibia were obtained. The maximum flexibility of the right and the left tibia was (2.737 +/- 0.262) mm and (2.739 +/- 0.233) mm respectively. The maximum load, which indicated the bending strength, of the right and the left tibia was (17.803 +/- 2.675) kg and (18.366 +/- 2.653) kg respectively. The area under the load-flexibility curve before fail of the right and the left tibia was (23.829 +/- 4.413) kg/mm and (24.725 +/- 4.101) kg x mm respectively. The slope of the load-flexibility curve which indicate the stiffness of the right and the left tibia was (7.545 +/- 1.310) kg/mm and (7.631 +/- 1.174) kg x mm respectively. CONCLUSION: The discrepancy between different animal body is larger than conventionally required. It's suggested for performing three-point bending test of long bone of the body both sides in pair.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To explore the mechanical property of intact long bone through three-point bending test of rabbit tibia according to mechanics of materials. METHODS: Ten pairs of normal rabbits tibia were treated on three-point bending test with 80 mm supporting distance in order to corroborate the virtual loading test on bone model. RESULTS: Bending stiffness and strength of 10 pairs of normal rabbit tibia were obtained. The maximum flexibility of the right and the left tibia was (2.737 +/- 0.262) mm and (2.739 +/- 0.233) mm respectively. The maximum load, which indicated the bending strength, of the right and the left tibia was (17.803 +/- 2.675) kg and (18.366 +/- 2.653) kg respectively. The area under the load-flexibility curve before fail of the right and the left tibia was (23.829 +/- 4.413) kg/mm and (24.725 +/- 4.101) kg x mm respectively. The slope of the load-flexibility curve which indicate the stiffness of the right and the left tibia was (7.545 +/- 1.310) kg/mm and (7.631 +/- 1.174) kg x mm respectively. CONCLUSION: The discrepancy between different animal body is larger than conventionally required. It's suggested for performing three-point bending test of long bone of the body both sides in pair.
Key concepts: Tibia, Bending, Flexibility (engineering), Three point flexural test, Medicine, Stiffness, Anatomy, Bending stiffness