Applied of Serum Ascitic Albumingradient in Differential Diagnosis of Ascitic Etiologies
Chen Tianjian
Abstract
Chen Tianjian
Abstract
Objective To evaluate the diagnostic value and reliability of SAAG and other laboratory tests in patients with ascites.Methods Case records of 106 patients with ascites were reviewed retrospectively.The patients were divided into 2 groups,the groups associated with portalhypertension(60 patients)and the group without portal hypertension(46 patients).The SAAG were calculated using the serum and ascitic albuminlevels on the same day.Results The mean level and standard deviation of SAAG of the group associated with portal hypertension and the group without portal hypertension was(18.27±2.05)g/L,and(6.72±1.38)g/L,respectively(P0.001).Using SAAG≥11 g/L as the cut-off value,the diagnostic sensitivity for ascites associated with portal hypertension was 96.67%,diagnostic specificity was 91.30%,diagnosticaccuracy 94.34%.Conclusion The coincidence rate of SAAG differentiation method is evidently higher than the traditional ascites differentiation methods,but it can't instead of the detection of ascitic haryotes number and cytological detection.Therefore,the associated detection of the two methods would effectively increase the accurate rate of the diagnosis of the couse of ascities.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the diagnostic value and reliability of SAAG and other laboratory tests in patients with ascites.Methods Case records of 106 patients with ascites were reviewed retrospectively.The patients were divided into 2 groups,the groups associated with portalhypertension(60 patients)and the group without portal hypertension(46 patients).The SAAG were calculated using the serum and ascitic albuminlevels on the same day.Results The mean level and standard deviation of SAAG of the group associated with portal hypertension and the group without portal hypertension was(18.27±2.05)g/L,and(6.72±1.38)g/L,respectively(P0.001).Using SAAG≥11 g/L as the cut-off value,the diagnostic sensitivity for ascites associated with portal hypertension was 96.67%,diagnostic specificity was 91.30%,diagnosticaccuracy 94.34%.Conclusion The coincidence rate of SAAG differentiation method is evidently higher than the traditional ascites differentiation methods,but it can't instead of the detection of ascitic haryotes number and cytological detection.Therefore,the associated detection of the two methods would effectively increase the accurate rate of the diagnosis of the couse of ascities.
Key concepts: Medicine, Ascites, Portal hypertension, Gastroenterology, Internal medicine, Differential diagnosis, Ascitic fluid, Etiology