2001Journal of Nanchang UniversityRequires access

STUDY ON THE DETERMINATION OF TRACE Cd(II) BY CATALYTIC KINETIC-SPECTROPHOTOMETRY

Xiang Huang

Open publisher page 0 citations

Abstract

It has been studied that in H 3BO 3-KCl-Na 2CO 3 trace Cd(Ⅱ) can sensitively catalyze the new indicative reaction of (NH 4) 2S 2O 8 oxidizing discoloration of the pyrogallol red.The kinetic optimum conditioins and mechanism of the reaction were investigated in detail and a new method for the determination of trace cadmium was proposed.The detection limit is 6.9×10 -6 mg/mL and the linear range of determination is 0.0-10.0 μg/25 mL.It has been satisfactorily applied to the determination of trace Cd(Ⅱ) in the waste water.

About this research paper

What this paper is about

It has been studied that in H 3BO 3-KCl-Na 2CO 3 trace Cd(Ⅱ) can sensitively catalyze the new indicative reaction of (NH 4) 2S 2O 8 oxidizing discoloration of the pyrogallol red.The kinetic optimum conditioins and mechanism of the reaction were investigated in detail and a new method for the determination of trace cadmium was proposed.The detection limit is 6.9×10 -6 mg/mL and the linear range of determination is 0.0-10.0 μg/25 mL.It has been satisfactorily applied to the determination of trace Cd(Ⅱ) in the waste water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It has been studied that in H 3BO 3-KCl-Na 2CO 3 trace Cd(Ⅱ) can sensitively catalyze the new indicative reaction of (NH 4) 2S 2O 8 oxidizing discoloration of the pyrogallol red.The kinetic optimum conditioins and mechanism of the reaction were investigated in detail and a new method for the determination of trace cadmium was proposed.The detection limit is 6.9×10 -6 mg/mL and the linear range of determination is 0.0-10.0 μg/25 mL.It has been satisfactorily applied to the determination of trace Cd(Ⅱ) in the waste water.

Key concepts: Detection limit, Pyrogallol, Oxidizing agent, Linear range, Chemistry, TRACE (psycholinguistics), Spectrophotometry, Cadmium

Related papers

Back to paper searchBrowse research topicsOriginal source
STUDY ON THE DETERMINATION OF TRACE Cd(II) BY CATALYTIC KINETIC-SPECTROPHOTOMETRY — Research Paper | ScholarLens