2011Metallurgical AnalysisRequires access

Determination of copper by differential pulse voltammetry based on hematoxylin and graphene modified glassy carbon electrode

Gao Ying-ying

Open publisher page 0 citations

Abstract

Graphene was coated on glassy carbon electrode(GCE) while hematoxylin was electrodeposited on the graphene film to construct the modified electrode.Electrochemical method for trace copper determination was developed using this modified electrode with differential pulse voltammetry.It was indicated that the peak currents varied linearly with the concentration of Cu2+ over the range from 5×10-8 to 2×10-6 mol/L with the correlation coefficent of 0.992 and 0.996,through the determination of peak current at 0.13 V after the sample was accumulated for 4 min at-0.3 V in a 0.1 mol/L pH 4.2 NaAc-HAc buffer.The detection limit was 2×10-9 mol/L.The proposed method was used to determine trace copper in industrial wastewater with the relative standard deviations of 4.3%-5.7%.The results agreed well with those obtained by ICP-AES method.

About this research paper

What this paper is about

Graphene was coated on glassy carbon electrode(GCE) while hematoxylin was electrodeposited on the graphene film to construct the modified electrode.Electrochemical method for trace copper determination was developed using this modified electrode with differential pulse voltammetry.It was indicated that the peak currents varied linearly with the concentration of Cu2+ over the range from 5×10-8 to 2×10-6 mol/L with the correlation coefficent of 0.992 and 0.996,through the determination of peak current at 0.13 V after the sample was accumulated for 4 min at-0.3 V in a 0.1 mol/L pH 4.2 NaAc-HAc buffer.The detection limit was 2×10-9 mol/L.The proposed method was used to determine trace copper in industrial wastewater with the relative standard deviations of 4.3%-5.7%.The results agreed well with those obtained by ICP-AES method.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Graphene was coated on glassy carbon electrode(GCE) while hematoxylin was electrodeposited on the graphene film to construct the modified electrode.Electrochemical method for trace copper determination was developed using this modified electrode with differential pulse voltammetry.It was indicated that the peak currents varied linearly with the concentration of Cu2+ over the range from 5×10-8 to 2×10-6 mol/L with the correlation coefficent of 0.992 and 0.996,through the determination of peak current at 0.13 V after the sample was accumulated for 4 min at-0.3 V in a 0.1 mol/L pH 4.2 NaAc-HAc buffer.The detection limit was 2×10-9 mol/L.The proposed method was used to determine trace copper in industrial wastewater with the relative standard deviations of 4.3%-5.7%.The results agreed well with those obtained by ICP-AES method.

Key concepts: Differential pulse voltammetry, Copper, Analytical Chemistry (journal), Graphene, Detection limit, Electrode, Electrochemistry, Cyclic voltammetry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of copper by differential pulse voltammetry based on hematoxylin and graphene modified glassy carbon electrode — Research Paper | ScholarLens