Assessment of right ventricular systolic function by real-time three-dimensional echocardiography:animal experimental and clinical study
Zi-Ning Yan
Abstract
Zi-Ning Yan
Abstract
Objective To assess the right ventricular systolic function of healthy individuals and patients with atrial septal defect(ASD)by used real-time three-dimensional echocardiography 4D RV-Function(4D-RVF)off-line analysis software. Methods Full-volume of RT-3DE was performed in 93 healthy individuals(NOR)and 15 patients with atrial septal defect (ASD).Right ventricular end diastolic volume(RVEDV),end systolic volume(RVESV),stroke volume(RVSV)and right ventricular ejection fraction(RVEF)were measured using 4D-RVF method;Full-volume of real-time three-dimensional (RT-3DE)was also performed in 10 excised fresh pig hearts,and the right ventricular volumes were measured by both 4D- RVF and apical long-axis 8 plane(AL 8-plane,4D Cardio-View)methods.The parameters were compared with actual vol- ume respectively.Results Right ventricular volume parameters of healthy individuals(NOR)obtained from 4D-RVF were as follows:RVEDV:(90.57±28.27)ml,RVESV:(38.325±14.18)ml,RVSV:(52.25±16.86)ml,RVEF:(57.96±6.85)%;RV systolic function was decreased in ASD patients.In excised pig hearts,the right ventricular volume obtained from 4D-RVF method was very close to the actual volume(r_1=0.93,r_2=0.82).Conclusion Real-time three-dimensional echocardiography-4D RV-Function(4D-RVF)method can assess the right ventricular systolic function accurately.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To assess the right ventricular systolic function of healthy individuals and patients with atrial septal defect(ASD)by used real-time three-dimensional echocardiography 4D RV-Function(4D-RVF)off-line analysis software. Methods Full-volume of RT-3DE was performed in 93 healthy individuals(NOR)and 15 patients with atrial septal defect (ASD).Right ventricular end diastolic volume(RVEDV),end systolic volume(RVESV),stroke volume(RVSV)and right ventricular ejection fraction(RVEF)were measured using 4D-RVF method;Full-volume of real-time three-dimensional (RT-3DE)was also performed in 10 excised fresh pig hearts,and the right ventricular volumes were measured by both 4D- RVF and apical long-axis 8 plane(AL 8-plane,4D Cardio-View)methods.The parameters were compared with actual vol- ume respectively.Results Right ventricular volume parameters of healthy individuals(NOR)obtained from 4D-RVF were as follows:RVEDV:(90.57±28.27)ml,RVESV:(38.325±14.18)ml,RVSV:(52.25±16.86)ml,RVEF:(57.96±6.85)%;RV systolic function was decreased in ASD patients.In excised pig hearts,the right ventricular volume obtained from 4D-RVF method was very close to the actual volume(r_1=0.93,r_2=0.82).Conclusion Real-time three-dimensional echocardiography-4D RV-Function(4D-RVF)method can assess the right ventricular systolic function accurately.
Key concepts: Medicine, Cardiology, Internal medicine, Ventricular volume, Stroke volume, Ventricular function, End-systolic volume, Ejection fraction