2008Zhongguo yixue yingxiang jishuRequires access

Assessment of right ventricular systolic function by real-time three-dimensional echocardiography:animal experimental and clinical study

Zi-Ning Yan

Open publisher page 0 citations

Abstract

Objective To assess the right ventricular systolic function of healthy individuals and patients with atrial septal defect(ASD)by used real-time three-dimensional echocardiography 4D RV-Function(4D-RVF)off-line analysis software. Methods Full-volume of RT-3DE was performed in 93 healthy individuals(NOR)and 15 patients with atrial septal defect (ASD).Right ventricular end diastolic volume(RVEDV),end systolic volume(RVESV),stroke volume(RVSV)and right ventricular ejection fraction(RVEF)were measured using 4D-RVF method;Full-volume of real-time three-dimensional (RT-3DE)was also performed in 10 excised fresh pig hearts,and the right ventricular volumes were measured by both 4D- RVF and apical long-axis 8 plane(AL 8-plane,4D Cardio-View)methods.The parameters were compared with actual vol- ume respectively.Results Right ventricular volume parameters of healthy individuals(NOR)obtained from 4D-RVF were as follows:RVEDV:(90.57±28.27)ml,RVESV:(38.325±14.18)ml,RVSV:(52.25±16.86)ml,RVEF:(57.96±6.85)%;RV systolic function was decreased in ASD patients.In excised pig hearts,the right ventricular volume obtained from 4D-RVF method was very close to the actual volume(r_1=0.93,r_2=0.82).Conclusion Real-time three-dimensional echocardiography-4D RV-Function(4D-RVF)method can assess the right ventricular systolic function accurately.

About this research paper

What this paper is about

Objective To assess the right ventricular systolic function of healthy individuals and patients with atrial septal defect(ASD)by used real-time three-dimensional echocardiography 4D RV-Function(4D-RVF)off-line analysis software. Methods Full-volume of RT-3DE was performed in 93 healthy individuals(NOR)and 15 patients with atrial septal defect (ASD).Right ventricular end diastolic volume(RVEDV),end systolic volume(RVESV),stroke volume(RVSV)and right ventricular ejection fraction(RVEF)were measured using 4D-RVF method;Full-volume of real-time three-dimensional (RT-3DE)was also performed in 10 excised fresh pig hearts,and the right ventricular volumes were measured by both 4D- RVF and apical long-axis 8 plane(AL 8-plane,4D Cardio-View)methods.The parameters were compared with actual vol- ume respectively.Results Right ventricular volume parameters of healthy individuals(NOR)obtained from 4D-RVF were as follows:RVEDV:(90.57±28.27)ml,RVESV:(38.325±14.18)ml,RVSV:(52.25±16.86)ml,RVEF:(57.96±6.85)%;RV systolic function was decreased in ASD patients.In excised pig hearts,the right ventricular volume obtained from 4D-RVF method was very close to the actual volume(r_1=0.93,r_2=0.82).Conclusion Real-time three-dimensional echocardiography-4D RV-Function(4D-RVF)method can assess the right ventricular systolic function accurately.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the right ventricular systolic function of healthy individuals and patients with atrial septal defect(ASD)by used real-time three-dimensional echocardiography 4D RV-Function(4D-RVF)off-line analysis software. Methods Full-volume of RT-3DE was performed in 93 healthy individuals(NOR)and 15 patients with atrial septal defect (ASD).Right ventricular end diastolic volume(RVEDV),end systolic volume(RVESV),stroke volume(RVSV)and right ventricular ejection fraction(RVEF)were measured using 4D-RVF method;Full-volume of real-time three-dimensional (RT-3DE)was also performed in 10 excised fresh pig hearts,and the right ventricular volumes were measured by both 4D- RVF and apical long-axis 8 plane(AL 8-plane,4D Cardio-View)methods.The parameters were compared with actual vol- ume respectively.Results Right ventricular volume parameters of healthy individuals(NOR)obtained from 4D-RVF were as follows:RVEDV:(90.57±28.27)ml,RVESV:(38.325±14.18)ml,RVSV:(52.25±16.86)ml,RVEF:(57.96±6.85)%;RV systolic function was decreased in ASD patients.In excised pig hearts,the right ventricular volume obtained from 4D-RVF method was very close to the actual volume(r_1=0.93,r_2=0.82).Conclusion Real-time three-dimensional echocardiography-4D RV-Function(4D-RVF)method can assess the right ventricular systolic function accurately.

Key concepts: Medicine, Cardiology, Internal medicine, Ventricular volume, Stroke volume, Ventricular function, End-systolic volume, Ejection fraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of right ventricular systolic function by real-time three-dimensional echocardiography:animal experimental and clinical study — Research Paper | ScholarLens