2010Chinese Journal of Medical UltrasoundRequires access

Clinical effect of color Doppler imaging in monitoring patients with extensive portal vein thrombosis during liver transplantation: an analysis of 4 cases

Zhu Xiao-fen

Open publisher page 0 citations

Abstract

Objective To assess the effect of color Doppler imaging(CDI) in mornitoring patients with extensive portal vein thrombosis in the perioperative period of liver transplantation.Methods The sequoia 512 color Doppler were used in 4 cases of patients with extensive portal vein thrombosis before and after liver transplantation.2.5-5.0 MHz ultrasound probe were used to monitor the maximum diameter of portal vein,average blood flow velocity,maximum velocity,flow spectrum and collateral circulation.Results Before liver transplantation,the anomalies of portal vein through CDI were observed in 4 patients,such as slow or no blood flow in portal vein,severe segmental stenosis,completely blocked and severe intimal lesions of portal vein.The multiple branches of collateral circulation,expansion of the superior mesenteric vein and unsuitable condition for reconstruction of portal vein were also found.These findings of CDI were confirmed at surgery,which could help us in reconstruction of blood perfusion to donor liver.Postoperative monitoring of CDI was adopted once at an interval day for two weeks.The diameter of reconstructed portal vein,the velocity and direction of blood flow in the portal vein were found as normal.Conclusion CDI has effective in monitoring complications of portal vein thrombosis after liver transplantation,which could not only help the preoperative design but also guide the operation during liver transplantation.

About this research paper

What this paper is about

Objective To assess the effect of color Doppler imaging(CDI) in mornitoring patients with extensive portal vein thrombosis in the perioperative period of liver transplantation.Methods The sequoia 512 color Doppler were used in 4 cases of patients with extensive portal vein thrombosis before and after liver transplantation.2.5-5.0 MHz ultrasound probe were used to monitor the maximum diameter of portal vein,average blood flow velocity,maximum velocity,flow spectrum and collateral circulation.Results Before liver transplantation,the anomalies of portal vein through CDI were observed in 4 patients,such as slow or no blood flow in portal vein,severe segmental stenosis,completely blocked and severe intimal lesions of portal vein.The multiple branches of collateral circulation,expansion of the superior mesenteric vein and unsuitable condition for reconstruction of portal vein were also found.These findings of CDI were confirmed at surgery,which could help us in reconstruction of blood perfusion to donor liver.Postoperative monitoring of CDI was adopted once at an interval day for two weeks.The diameter of reconstructed portal vein,the velocity and direction of blood flow in the portal vein were found as normal.Conclusion CDI has effective in monitoring complications of portal vein thrombosis after liver transplantation,which could not only help the preoperative design but also guide the operation during liver transplantation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the effect of color Doppler imaging(CDI) in mornitoring patients with extensive portal vein thrombosis in the perioperative period of liver transplantation.Methods The sequoia 512 color Doppler were used in 4 cases of patients with extensive portal vein thrombosis before and after liver transplantation.2.5-5.0 MHz ultrasound probe were used to monitor the maximum diameter of portal vein,average blood flow velocity,maximum velocity,flow spectrum and collateral circulation.Results Before liver transplantation,the anomalies of portal vein through CDI were observed in 4 patients,such as slow or no blood flow in portal vein,severe segmental stenosis,completely blocked and severe intimal lesions of portal vein.The multiple branches of collateral circulation,expansion of the superior mesenteric vein and unsuitable condition for reconstruction of portal vein were also found.These findings of CDI were confirmed at surgery,which could help us in reconstruction of blood perfusion to donor liver.Postoperative monitoring of CDI was adopted once at an interval day for two weeks.The diameter of reconstructed portal vein,the velocity and direction of blood flow in the portal vein were found as normal.Conclusion CDI has effective in monitoring complications of portal vein thrombosis after liver transplantation,which could not only help the preoperative design but also guide the operation during liver transplantation.

Key concepts: Medicine, Portal vein thrombosis, Liver transplantation, Thrombosis, Radiology, Blood flow, Transplantation, Splenic vein

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical effect of color Doppler imaging in monitoring patients with extensive portal vein thrombosis during liver transplantation: an analysis of 4 cases — Research Paper | ScholarLens