2015•PubMedRequires access

[Research on Constant-current Characteristics of Howland Current Source Used in Bioelectrical Impedance Detection].

Xingjian Lin, Weijie Zhao, Xiaojuan Liu, Li-Hua Li

Open publisher page 0 citations

Abstract

This study aims to analyze and improve Howland current source circuit and to study the constant current source of alternating current with high output impedance and high stability. A simulation study was carried out on the constant-current characteristics of Howland current source from two aspects of resistance match value and the selection of Op amp parameters, and then the output impedance was analyzed. The simulation experiment showed that when it was with the best matched resistance, the constant-current characteristics of Howland current source was better. Op amp parameters could affect the constant-current characteristics of Howland current source. In Howland current source circuit, the current source after parameter optimization had better output impedance and load capacity. The results showed that there was the best matched resistance in the selection by Howland current source. The Op amp with large broadband, high slew rate and open loop gain, and wide range of power supply voltage is more suitable for the bioelectrical impedance detection circuit.

About this research paper

What this paper is about

This study aims to analyze and improve Howland current source circuit and to study the constant current source of alternating current with high output impedance and high stability. A simulation study was carried out on the constant-current characteristics of Howland current source from two aspects of resistance match value and the selection of Op amp parameters, and then the output impedance was analyzed. The simulation experiment showed that when it was with the best matched resistance, the constant-current characteristics of Howland current source was better. Op amp parameters could affect the constant-current characteristics of Howland current source. In Howland current source circuit, the current source after parameter optimization had better output impedance and load capacity. The results showed that there was the best matched resistance in the selection by Howland current source. The Op amp with large broadband, high slew rate and open loop gain, and wide range of power supply voltage is more suitable for the bioelectrical impedance detection circuit.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study aims to analyze and improve Howland current source circuit and to study the constant current source of alternating current with high output impedance and high stability. A simulation study was carried out on the constant-current characteristics of Howland current source from two aspects of resistance match value and the selection of Op amp parameters, and then the output impedance was analyzed. The simulation experiment showed that when it was with the best matched resistance, the constant-current characteristics of Howland current source was better. Op amp parameters could affect the constant-current characteristics of Howland current source. In Howland current source circuit, the current source after parameter optimization had better output impedance and load capacity. The results showed that there was the best matched resistance in the selection by Howland current source. The Op amp with large broadband, high slew rate and open loop gain, and wide range of power supply voltage is more suitable for the bioelectrical impedance detection circuit.

Key concepts: Current source, Current (fluid), Output impedance, Constant current, Electrical impedance, Voltage source, Voltage, Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
[Research on Constant-current Characteristics of Howland Current Source Used in Bioelectrical Impedance Detection]. — Research Paper | ScholarLens