2004Liaoning Chemical IndustryRequires access

The Determination of Trace Selenium in Samples by Hydride Generation─Atomic Fluorescence Spectrometry

Zhu Chun-juan

Open publisher page 0 citations

Abstract

In this thesis, a method was developed for the determination of trace selenium in biological, agricultural and environmental samples by hydride generation ─ atomic fluorescence spectrometry. The factors that affected the determination of selenium such as the concentration of HCl, KBH 4, the instrument parameters and coexistent elements were optimized. Under the optimum conditions, the detection limits of the method was 0.32 μg/L, the relative standard deviation was less than 0.4 %, the recovery rate of samples were ranged from 93 % to 102 %.

About this research paper

What this paper is about

In this thesis, a method was developed for the determination of trace selenium in biological, agricultural and environmental samples by hydride generation ─ atomic fluorescence spectrometry. The factors that affected the determination of selenium such as the concentration of HCl, KBH 4, the instrument parameters and coexistent elements were optimized. Under the optimum conditions, the detection limits of the method was 0.32 μg/L, the relative standard deviation was less than 0.4 %, the recovery rate of samples were ranged from 93 % to 102 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this thesis, a method was developed for the determination of trace selenium in biological, agricultural and environmental samples by hydride generation ─ atomic fluorescence spectrometry. The factors that affected the determination of selenium such as the concentration of HCl, KBH 4, the instrument parameters and coexistent elements were optimized. Under the optimum conditions, the detection limits of the method was 0.32 μg/L, the relative standard deviation was less than 0.4 %, the recovery rate of samples were ranged from 93 % to 102 %.

Key concepts: Selenium, Hydride, Chemistry, Detection limit, Relative standard deviation, Mass spectrometry, TRACE (psycholinguistics), Fluorescence spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
The Determination of Trace Selenium in Samples by Hydride Generation─Atomic Fluorescence Spectrometry — Research Paper | ScholarLens