Research on Three-phase Partial Active Power Factor Correction
Lei Huai-gang
Abstract
Lei Huai-gang
Abstract
Higher power inverter-fed air-conditioner is powered by three-phase AC power supply with wide applications,bringing about the issue of the power factor correction(PFC) for three-phase rectifiers.Two three-phase partial active PFC is presented respectively for three-phase three-wire system and three-phase four-wire system,which incorporate active PFC and passive PFC techniques.Based on the description of working principle,the experiments are carried out,and the results prove the features of three-phase partial PFC of low voltage and current stresses,high efficiency,higher power factor and higher DC average voltage.The harmonics current are consistent with IEC61000-3-2 at any load,and the power factor is higher up to 0.98,and the efficiency is above 0.98 at above medium load.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Higher power inverter-fed air-conditioner is powered by three-phase AC power supply with wide applications,bringing about the issue of the power factor correction(PFC) for three-phase rectifiers.Two three-phase partial active PFC is presented respectively for three-phase three-wire system and three-phase four-wire system,which incorporate active PFC and passive PFC techniques.Based on the description of working principle,the experiments are carried out,and the results prove the features of three-phase partial PFC of low voltage and current stresses,high efficiency,higher power factor and higher DC average voltage.The harmonics current are consistent with IEC61000-3-2 at any load,and the power factor is higher up to 0.98,and the efficiency is above 0.98 at above medium load.
Key concepts: Power factor, Harmonics, AC power, Three-phase, Power (physics), Voltage, Switched-mode power supply, Phase (matter)