2013•Ningxia Medical JournalRequires access

Research on determination of bromate in flour and flour products by Ion chro-matography

Gao Gui-ta

Open publisher page 0 citations

Abstract

Objective To establish a method for determination of bromate in flour and its products by ion chromatography.Methods Bromate was first extracted from the sample by oscillation with pure water,then the supernatant liquid was centrifuged,and the RP,Ag / H column was employed to remove protein and chloride,then the solution was filtrated through 0.22 μm filter membrane to ultrafiltration,finally the suppressed conductivity detector was used for detection after separation with DIONEX IonPac AS19 and elution with sodium hydroxide solution.Results The linear range was 1.0 μg.mL-1 ~ 6.0 μg.mL-1 for bromate with correlation coefficients of more than 0.9998,the detection limit was e 0.50 mg.kg-1,the recoveries were 85% ~99%.Conclusion The developed method is satisfied with the determination for bromate in flour and its products.

About this research paper

What this paper is about

Objective To establish a method for determination of bromate in flour and its products by ion chromatography.Methods Bromate was first extracted from the sample by oscillation with pure water,then the supernatant liquid was centrifuged,and the RP,Ag / H column was employed to remove protein and chloride,then the solution was filtrated through 0.22 μm filter membrane to ultrafiltration,finally the suppressed conductivity detector was used for detection after separation with DIONEX IonPac AS19 and elution with sodium hydroxide solution.Results The linear range was 1.0 μg.mL-1 ~ 6.0 μg.mL-1 for bromate with correlation coefficients of more than 0.9998,the detection limit was e 0.50 mg.kg-1,the recoveries were 85% ~99%.Conclusion The developed method is satisfied with the determination for bromate in flour and its products.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for determination of bromate in flour and its products by ion chromatography.Methods Bromate was first extracted from the sample by oscillation with pure water,then the supernatant liquid was centrifuged,and the RP,Ag / H column was employed to remove protein and chloride,then the solution was filtrated through 0.22 μm filter membrane to ultrafiltration,finally the suppressed conductivity detector was used for detection after separation with DIONEX IonPac AS19 and elution with sodium hydroxide solution.Results The linear range was 1.0 μg.mL-1 ~ 6.0 μg.mL-1 for bromate with correlation coefficients of more than 0.9998,the detection limit was e 0.50 mg.kg-1,the recoveries were 85% ~99%.Conclusion The developed method is satisfied with the determination for bromate in flour and its products.

Key concepts: Bromate, Ultrafiltration (renal), Chromatography, Sodium hydroxide, Detection limit, Ion chromatography, Hydroxide, Thermal conductivity detector

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on determination of bromate in flour and flour products by Ion chro-matography — Research Paper | ScholarLens