2007Medical InformationRequires access

The study on the Method for Detecting Trigeminal Evoked Potentials in Rats

Yincheng Zhang

Open publisher page 0 citations

Abstract

Objective Explore the accurate method for detecting brain trigeminal(BTEP)in rats.Methods Detecting brain trigeminal evoked potentials through comparative research with different methods in stimulation and recording by multi-channels evoked potentials apparatus.Result The waveform of BTEP is steady in Cz-Cv7 lead and stimulus duration at 0.04ms.The waveform is in good interference immunity and almost symmetrical in double side.And the parameter about BTEP is stabile.Conclusion We think it a good method in examining BTEP using Cz-Cv7 lead and stimulus duration at 0.04ms.

About this research paper

What this paper is about

Objective Explore the accurate method for detecting brain trigeminal(BTEP)in rats.Methods Detecting brain trigeminal evoked potentials through comparative research with different methods in stimulation and recording by multi-channels evoked potentials apparatus.Result The waveform of BTEP is steady in Cz-Cv7 lead and stimulus duration at 0.04ms.The waveform is in good interference immunity and almost symmetrical in double side.And the parameter about BTEP is stabile.Conclusion We think it a good method in examining BTEP using Cz-Cv7 lead and stimulus duration at 0.04ms.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective Explore the accurate method for detecting brain trigeminal(BTEP)in rats.Methods Detecting brain trigeminal evoked potentials through comparative research with different methods in stimulation and recording by multi-channels evoked potentials apparatus.Result The waveform of BTEP is steady in Cz-Cv7 lead and stimulus duration at 0.04ms.The waveform is in good interference immunity and almost symmetrical in double side.And the parameter about BTEP is stabile.Conclusion We think it a good method in examining BTEP using Cz-Cv7 lead and stimulus duration at 0.04ms.

Key concepts: Stimulus (psychology), Waveform, Evoked potential, Audiology, Stimulation, Duration (music), Neuroscience, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The study on the Method for Detecting Trigeminal Evoked Potentials in Rats — Research Paper | ScholarLens