2009Chemical engineerRequires access

Determination of lactic acid and acrycis acid in reactive liquor of lactic acid catalytic preparing acrycis acid

HE Tie-shanb

Open publisher page 0 citations

Abstract

A method about the determination of lactic acid and acrycis acid in reactive liquor of lactic acid catalytic preparing acrycis acid by gas chromatograply was set up. It was separated well with 10% PEG-20M packed column (3×3mm) under the flow rate of carrier gas (nitrogen) 30mL·min-1, the flow rate of hydrogen gas 88 mL·min-1, the flow rate of air 300 mL·min-1, the temperature of feed-entrance and detector 160℃, the temperature of column 150℃. It was detected with FID detector using (n-)butanol as an internal standard. The linear correlative coefficient of lactic acid and acrycis acid were 0.9994 and 0.9996, RSD were 0.74% and 0.56% , the average recovery were 97.35% and 97.60% , the detection limit were 8.62mg·L-1 and 1.21 mg·L-1. This method was convenient rapid and accurate.

About this research paper

What this paper is about

A method about the determination of lactic acid and acrycis acid in reactive liquor of lactic acid catalytic preparing acrycis acid by gas chromatograply was set up. It was separated well with 10% PEG-20M packed column (3×3mm) under the flow rate of carrier gas (nitrogen) 30mL·min-1, the flow rate of hydrogen gas 88 mL·min-1, the flow rate of air 300 mL·min-1, the temperature of feed-entrance and detector 160℃, the temperature of column 150℃. It was detected with FID detector using (n-)butanol as an internal standard. The linear correlative coefficient of lactic acid and acrycis acid were 0.9994 and 0.9996, RSD were 0.74% and 0.56% , the average recovery were 97.35% and 97.60% , the detection limit were 8.62mg·L-1 and 1.21 mg·L-1. This method was convenient rapid and accurate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method about the determination of lactic acid and acrycis acid in reactive liquor of lactic acid catalytic preparing acrycis acid by gas chromatograply was set up. It was separated well with 10% PEG-20M packed column (3×3mm) under the flow rate of carrier gas (nitrogen) 30mL·min-1, the flow rate of hydrogen gas 88 mL·min-1, the flow rate of air 300 mL·min-1, the temperature of feed-entrance and detector 160℃, the temperature of column 150℃. It was detected with FID detector using (n-)butanol as an internal standard. The linear correlative coefficient of lactic acid and acrycis acid were 0.9994 and 0.9996, RSD were 0.74% and 0.56% , the average recovery were 97.35% and 97.60% , the detection limit were 8.62mg·L-1 and 1.21 mg·L-1. This method was convenient rapid and accurate.

Key concepts: Lactic acid, Chemistry, Chromatography, Catalysis, Volumetric flow rate, Detection limit, Hydrogen, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of lactic acid and acrycis acid in reactive liquor of lactic acid catalytic preparing acrycis acid — Research Paper | ScholarLens