2011•Journal of Northwest University for NationalitiesRequires access

Solid-Phase Extraction-high Performance Liquid Chromatographic Detection Tetracycline Class Antibiotic Residues in Beef

Cheng Yan-ping

Open publisher page 0 citations

Abstract

To establish quantitative analysis tetracycline class antibiotic residue of method to use solid-phase extraction-HPLC ultraviolet detection in beef.The residual tetracycline class antibiotic were determined in beef by using Waters 2695 high-performance liquid chromatography.The sample by 5% perchloric acid solution extraction,C18 solid phase extraction column purification,rotating enrichment,0.22μm microfiltration membrane filtration,reversed-phase chromatography separation,ultraviolet detection.chromatographic column for the Waters Nova-park C18 column(4 μm,3.9 mmi.d.×150 mm),with sodium dihydrogen phosphate solution-acetonitrile-methanol(volume ratio 70∶20∶10) as mobile phase,velocity for 0.8 mL/min,ultraviolet wavelength for 365 nm,each incoming sample 10 μL.The results showed that the oxytetracycline,tetracycline,aureomycin respectively detection limit of 0.0365 μg/mL,0.0430 μg/mL,0.0558 μg/mL, linear range for 0.1 μg/mL~1.0 μg/mL.Determination of 54 samples beef,only 1 samples beef aureomycin residue for 132 μg/kg,higher than China ministry of agriculture prescribed maximum permissible residues standard(100 μg/kg).In conclusion,the sale beef in lanzhou tetracycline antibiotic residues rate is not high(1/54).This article constructs solid-phase extraction-HPLC-ultraviolet assay determination beef tissues,such as oxytetracycline,tetracycline,aureomycin etc tetracycline class antibiotic residues are accurate and high accuracy.

About this research paper

What this paper is about

To establish quantitative analysis tetracycline class antibiotic residue of method to use solid-phase extraction-HPLC ultraviolet detection in beef.The residual tetracycline class antibiotic were determined in beef by using Waters 2695 high-performance liquid chromatography.The sample by 5% perchloric acid solution extraction,C18 solid phase extraction column purification,rotating enrichment,0.22μm microfiltration membrane filtration,reversed-phase chromatography separation,ultraviolet detection.chromatographic column for the Waters Nova-park C18 column(4 μm,3.9 mmi.d.×150 mm),with sodium dihydrogen phosphate solution-acetonitrile-methanol(volume ratio 70∶20∶10) as mobile phase,velocity for 0.8 mL/min,ultraviolet wavelength for 365 nm,each incoming sample 10 μL.The results showed that the oxytetracycline,tetracycline,aureomycin respectively detection limit of 0.0365 μg/mL,0.0430 μg/mL,0.0558 μg/mL, linear range for 0.1 μg/mL~1.0 μg/mL.Determination of 54 samples beef,only 1 samples beef aureomycin residue for 132 μg/kg,higher than China ministry of agriculture prescribed maximum permissible residues standard(100 μg/kg).In conclusion,the sale beef in lanzhou tetracycline antibiotic residues rate is not high(1/54).This article constructs solid-phase extraction-HPLC-ultraviolet assay determination beef tissues,such as oxytetracycline,tetracycline,aureomycin etc tetracycline class antibiotic residues are accurate and high accuracy.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To establish quantitative analysis tetracycline class antibiotic residue of method to use solid-phase extraction-HPLC ultraviolet detection in beef.The residual tetracycline class antibiotic were determined in beef by using Waters 2695 high-performance liquid chromatography.The sample by 5% perchloric acid solution extraction,C18 solid phase extraction column purification,rotating enrichment,0.22μm microfiltration membrane filtration,reversed-phase chromatography separation,ultraviolet detection.chromatographic column for the Waters Nova-park C18 column(4 μm,3.9 mmi.d.×150 mm),with sodium dihydrogen phosphate solution-acetonitrile-methanol(volume ratio 70∶20∶10) as mobile phase,velocity for 0.8 mL/min,ultraviolet wavelength for 365 nm,each incoming sample 10 μL.The results showed that the oxytetracycline,tetracycline,aureomycin respectively detection limit of 0.0365 μg/mL,0.0430 μg/mL,0.0558 μg/mL, linear range for 0.1 μg/mL~1.0 μg/mL.Determination of 54 samples beef,only 1 samples beef aureomycin residue for 132 μg/kg,higher than China ministry of agriculture prescribed maximum permissible residues standard(100 μg/kg).In conclusion,the sale beef in lanzhou tetracycline antibiotic residues rate is not high(1/54).This article constructs solid-phase extraction-HPLC-ultraviolet assay determination beef tissues,such as oxytetracycline,tetracycline,aureomycin etc tetracycline class antibiotic residues are accurate and high accuracy.

Key concepts: Chromatography, Oxytetracycline, Tetracycline, High-performance liquid chromatography, Chemistry, Residue (chemistry), Tetracycline antibiotics, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Solid-Phase Extraction-high Performance Liquid Chromatographic Detection Tetracycline Class Antibiotic Residues in Beef — Research Paper | ScholarLens