2005Radiologic PracticeRequires access

Evaluation of Pulmonary Nodules Using Low dose Spiral CT

Dan Han

Open publisher page 0 citations

Abstract

Objective:The purpose of this study is to investigate scanning parameters of low dose spiral CT in evaluation of pulmonary nodules and to evaluate low dose helical CT in chest compared with conventional dose helical CT.Methods:Eighty-eight pulmonary nodules of seventy-five patients underwent spiral CT scan with 200mA,40mA,30mA,20mA and 10mA respectively.The diameter,CT value and the highest CT value were measured.The different signs of the nodules were analyzed.So did the excessive noise and artifact of images.The weighted CT dose index (CTDIw) and milliampere seconds (mAs) were recorded.Results:There was no significant difference between the five groups in detection,diameter,CT value and all the signs within the nodules (P0.05).Noise and artifact of images in 10mAs group were higher than other groups (P0.05).There was significant difference about the data of the CTDIw between the conventional helical CT group and the other groups (40mA,30mA,20mA,10mA)(P0.05).Conclusion:20mA is the most appropriate milliampere for lung scanning.With the lower radiation and the higher sensitivity and the better price performance ratio,low-dose spiral CT is worthy to be used widely.

About this research paper

What this paper is about

Objective:The purpose of this study is to investigate scanning parameters of low dose spiral CT in evaluation of pulmonary nodules and to evaluate low dose helical CT in chest compared with conventional dose helical CT.Methods:Eighty-eight pulmonary nodules of seventy-five patients underwent spiral CT scan with 200mA,40mA,30mA,20mA and 10mA respectively.The diameter,CT value and the highest CT value were measured.The different signs of the nodules were analyzed.So did the excessive noise and artifact of images.The weighted CT dose index (CTDIw) and milliampere seconds (mAs) were recorded.Results:There was no significant difference between the five groups in detection,diameter,CT value and all the signs within the nodules (P0.05).Noise and artifact of images in 10mAs group were higher than other groups (P0.05).There was significant difference about the data of the CTDIw between the conventional helical CT group and the other groups (40mA,30mA,20mA,10mA)(P0.05).Conclusion:20mA is the most appropriate milliampere for lung scanning.With the lower radiation and the higher sensitivity and the better price performance ratio,low-dose spiral CT is worthy to be used widely.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:The purpose of this study is to investigate scanning parameters of low dose spiral CT in evaluation of pulmonary nodules and to evaluate low dose helical CT in chest compared with conventional dose helical CT.Methods:Eighty-eight pulmonary nodules of seventy-five patients underwent spiral CT scan with 200mA,40mA,30mA,20mA and 10mA respectively.The diameter,CT value and the highest CT value were measured.The different signs of the nodules were analyzed.So did the excessive noise and artifact of images.The weighted CT dose index (CTDIw) and milliampere seconds (mAs) were recorded.Results:There was no significant difference between the five groups in detection,diameter,CT value and all the signs within the nodules (P0.05).Noise and artifact of images in 10mAs group were higher than other groups (P0.05).There was significant difference about the data of the CTDIw between the conventional helical CT group and the other groups (40mA,30mA,20mA,10mA)(P0.05).Conclusion:20mA is the most appropriate milliampere for lung scanning.With the lower radiation and the higher sensitivity and the better price performance ratio,low-dose spiral CT is worthy to be used widely.

Key concepts: Medicine, Spiral (railway), Nuclear medicine, Radiology, Spiral computed tomography, Radiation dose, Computed tomography, Significant difference

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Pulmonary Nodules Using Low dose Spiral CT — Research Paper | ScholarLens