2009Shipin yanjiu yu kaifaRequires access

COMPARISON OF TWO METHODS OF TITRATION CALIBRATIONRESULTS OF HYDROCHLORIC ACID STANDARD SOLUTION

Peng Yang-si, Zhao Ting, Hua Zhang, Yang Liu, Wenjie Zheng

Open publisher page 0 citations

Abstract

Use automatic potentiometric titration and manual titration separately to calibrate hydrochloric acid standard solution, compare the result, in order to confirm the difference of calibrating results between the two kinds of methods. The method adopts the automatic potentiometric titration and calibrating method of hydrochloric acid standard solution provided by GB/T 601 -2002 and GB/T 5009.1 -2003, with anhydrous sodium carbonate for primary standard substance to calibrate the concentration of hydrochloric acid. Using two kinds of method to calibrate high concentration and low concentration hydrochloric acid solution, the results indicate there are no apparent differences. Furthermore, automatic potentiometric titration shows remarkable advantage than manual titration in calibrating high concentration of hydrochloric acid by comparing the standard deviation and relative standard deviation of the results of two methods.

About this research paper

What this paper is about

Use automatic potentiometric titration and manual titration separately to calibrate hydrochloric acid standard solution, compare the result, in order to confirm the difference of calibrating results between the two kinds of methods. The method adopts the automatic potentiometric titration and calibrating method of hydrochloric acid standard solution provided by GB/T 601 -2002 and GB/T 5009.1 -2003, with anhydrous sodium carbonate for primary standard substance to calibrate the concentration of hydrochloric acid. Using two kinds of method to calibrate high concentration and low concentration hydrochloric acid solution, the results indicate there are no apparent differences. Furthermore, automatic potentiometric titration shows remarkable advantage than manual titration in calibrating high concentration of hydrochloric acid by comparing the standard deviation and relative standard deviation of the results of two methods.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Use automatic potentiometric titration and manual titration separately to calibrate hydrochloric acid standard solution, compare the result, in order to confirm the difference of calibrating results between the two kinds of methods. The method adopts the automatic potentiometric titration and calibrating method of hydrochloric acid standard solution provided by GB/T 601 -2002 and GB/T 5009.1 -2003, with anhydrous sodium carbonate for primary standard substance to calibrate the concentration of hydrochloric acid. Using two kinds of method to calibrate high concentration and low concentration hydrochloric acid solution, the results indicate there are no apparent differences. Furthermore, automatic potentiometric titration shows remarkable advantage than manual titration in calibrating high concentration of hydrochloric acid by comparing the standard deviation and relative standard deviation of the results of two methods.

Key concepts: Hydrochloric acid, Potentiometric titration, Titration, Chemistry, Standard solution, Relative standard deviation, Gran plot, Standard addition

Related papers

Back to paper searchBrowse research topicsOriginal source
COMPARISON OF TWO METHODS OF TITRATION CALIBRATIONRESULTS OF HYDROCHLORIC ACID STANDARD SOLUTION — Research Paper | ScholarLens