Simultaneous determination of bensulfuron-methyl and mefenacet residues in paddy field using high performance liquid chromatography

Lihua Yang, Daoxin Gong, Jing Ping Tang, Junkai Luo, Chunxia Ding

Open full text 4 citations

Abstract

An analytical method of high performance liquid chromatography (HPLC) was established for the simultaneous determination of bensulfuron-methyl and mefenacet residues in paddy field (paddy water, soil and rice plant). The residues in the paddy water was extracted with methylene chloride, and the soil with alkaline mixed solution of acetonitrile-methylene chloride (1:1, v/v). The rice plant was extracted with alkaline methylene chloride which was cleaned up by a Florisil column. The separation was performed on a stainless steel C18 column (150 mm x 4.6 mm, 5 microm) at 30 degrees C by HPLC with an ultraviolet detector (UVD) at 238 nm, and water-methanol (30:70, v/v) as the mobile phase at a flow rate of 0.5 mL/min. The quantification was performed by external standard. The calibration curves were linear between the peak area and the concentration in the range of 0.05-5.00 mg/L for bensulfuron-methyl and mefenacet, and the correlation coefficients were more than 0.999 9. The average recoveries of the two herbicides spiked in the paddy water, soil and rice plant at the three concentration levels of 0.05, 0.10 and 1.00 mg/kg ranged from 85.39% to 113.33% with the relative standard deviations of 0.91%-10.24%. The method is characterized by simplicity, sensitivity and accuracy.

Open-access reader

About this research paper

What this paper is about

An analytical method of high performance liquid chromatography (HPLC) was established for the simultaneous determination of bensulfuron-methyl and mefenacet residues in paddy field (paddy water, soil and rice plant). The residues in the paddy water was extracted with methylene chloride, and the soil with alkaline mixed solution of acetonitrile-methylene chloride (1:1, v/v). The rice plant was extracted with alkaline methylene chloride which was cleaned up by a Florisil column. The separation was performed on a stainless steel C18 column (150 mm x 4.6 mm, 5 microm) at 30 degrees C by HPLC with an ultraviolet detector (UVD) at 238 nm, and water-methanol (30:70, v/v) as the mobile phase at a flow rate of 0.5 mL/min. The quantification was performed by external standard. The calibration curves were linear between the peak area and the concentration in the range of 0.05-5.00 mg/L for bensulfuron-methyl and mefenacet, and the correlation coefficients were more than 0.999 9. The average recoveries of the two herbicides spiked in the paddy water, soil and rice plant at the three concentration levels of 0.05, 0.10 and 1.00 mg/kg ranged from 85.39% to 113.33% with the relative standard deviations of 0.91%-10.24%. The method is characterized by simplicity, sensitivity and accuracy.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical method of high performance liquid chromatography (HPLC) was established for the simultaneous determination of bensulfuron-methyl and mefenacet residues in paddy field (paddy water, soil and rice plant). The residues in the paddy water was extracted with methylene chloride, and the soil with alkaline mixed solution of acetonitrile-methylene chloride (1:1, v/v). The rice plant was extracted with alkaline methylene chloride which was cleaned up by a Florisil column. The separation was performed on a stainless steel C18 column (150 mm x 4.6 mm, 5 microm) at 30 degrees C by HPLC with an ultraviolet detector (UVD) at 238 nm, and water-methanol (30:70, v/v) as the mobile phase at a flow rate of 0.5 mL/min. The quantification was performed by external standard. The calibration curves were linear between the peak area and the concentration in the range of 0.05-5.00 mg/L for bensulfuron-methyl and mefenacet, and the correlation coefficients were more than 0.999 9. The average recoveries of the two herbicides spiked in the paddy water, soil and rice plant at the three concentration levels of 0.05, 0.10 and 1.00 mg/kg ranged from 85.39% to 113.33% with the relative standard deviations of 0.91%-10.24%. The method is characterized by simplicity, sensitivity and accuracy.

Key concepts: Chemistry, Chromatography, High-performance liquid chromatography, Chloride, Calibration curve, Detection limit, Paddy field, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of bensulfuron-methyl and mefenacet residues in paddy field using high performance liquid chromatography — Research Paper | ScholarLens