2010•Traditional Chinese Drug Research and Clinical PharmacologyRequires access

Determination of Cinnamaldehyde in Zegui Longshuang Capsules by HPLC

Ling Cao

Open publisher page 0 citations

Abstract

Objective To establish a method for determining cinnamaldehyde in Zegui Longshuang Capsules. Methods A C18 column was used with Acetonitrile-Water (30∶70) as the mobile phase,and the detection wavelength was at 290 nm. Results The calibration curve of cinnamaldehyde was linear from 0.010 μg to 0.507 μg,and r=0.999 9. The average recovery was 98.55 %with RSD being 2.06 %. Conclusion This method is proved to be accurate and reliable,and can be used to control the quality of Zegui Longshuang Capsules.

About this research paper

What this paper is about

Objective To establish a method for determining cinnamaldehyde in Zegui Longshuang Capsules. Methods A C18 column was used with Acetonitrile-Water (30∶70) as the mobile phase,and the detection wavelength was at 290 nm. Results The calibration curve of cinnamaldehyde was linear from 0.010 μg to 0.507 μg,and r=0.999 9. The average recovery was 98.55 %with RSD being 2.06 %. Conclusion This method is proved to be accurate and reliable,and can be used to control the quality of Zegui Longshuang Capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for determining cinnamaldehyde in Zegui Longshuang Capsules. Methods A C18 column was used with Acetonitrile-Water (30∶70) as the mobile phase,and the detection wavelength was at 290 nm. Results The calibration curve of cinnamaldehyde was linear from 0.010 μg to 0.507 μg,and r=0.999 9. The average recovery was 98.55 %with RSD being 2.06 %. Conclusion This method is proved to be accurate and reliable,and can be used to control the quality of Zegui Longshuang Capsules.

Key concepts: Cinnamaldehyde, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Acetonitrile, Detection limit, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Cinnamaldehyde in Zegui Longshuang Capsules by HPLC — Research Paper | ScholarLens