2008•Hainan yixueRequires access

Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle

Huang Yu-liange

Open publisher page 0 citations

Abstract

Objectives To provide a safe transpedicular screw trajectory by measuring the dimensions of the cervical pedicle and evaluating the entrance points and the insertion angles of transpedicular screws.Methods The dimensions of the pedicles(C3-C27) were determined in 30 patients with cervical spinal lesions from CT images.CT images in which each pedicle appeared largest were selected and the following dimensions determined:pedicle inner and outer widths,medial cortical thickness,pedicle axis length and the pedicle transverse angle.Results The mean inner pedicle width ranged from 1.3 to 3.3mm,the mean outer pedicl width ranged from 4.0 to 7.0mm.The smallest pedicle Width was found at C3 among the female subjects for both inner and outer pedicles,The smallest outer pedicle width was 3.2mm,the largtest pedicle width was at C7 in both males(11.1mm) and females(7.4mm).The mean medial cortical thickness ranged from 1.5 to 2.0mm.The pedicle axis length ranged from 29.3 to 33.7mm.The mean pedicle transverse angle ranged from 39.8 to 49.0 degree.Conclusions Axial CT measurements should facilitate transpedicular screw fixation in the cervical spine.We believe that the screw insertion angle should be close to 50 degrees,which is the mean pedicle transverse angle from C3-C6.The entrypoint of the pedicle screw should be located as laterally as possible in the posterior surface of the lateral mass.

About this research paper

What this paper is about

Objectives To provide a safe transpedicular screw trajectory by measuring the dimensions of the cervical pedicle and evaluating the entrance points and the insertion angles of transpedicular screws.Methods The dimensions of the pedicles(C3-C27) were determined in 30 patients with cervical spinal lesions from CT images.CT images in which each pedicle appeared largest were selected and the following dimensions determined:pedicle inner and outer widths,medial cortical thickness,pedicle axis length and the pedicle transverse angle.Results The mean inner pedicle width ranged from 1.3 to 3.3mm,the mean outer pedicl width ranged from 4.0 to 7.0mm.The smallest pedicle Width was found at C3 among the female subjects for both inner and outer pedicles,The smallest outer pedicle width was 3.2mm,the largtest pedicle width was at C7 in both males(11.1mm) and females(7.4mm).The mean medial cortical thickness ranged from 1.5 to 2.0mm.The pedicle axis length ranged from 29.3 to 33.7mm.The mean pedicle transverse angle ranged from 39.8 to 49.0 degree.Conclusions Axial CT measurements should facilitate transpedicular screw fixation in the cervical spine.We believe that the screw insertion angle should be close to 50 degrees,which is the mean pedicle transverse angle from C3-C6.The entrypoint of the pedicle screw should be located as laterally as possible in the posterior surface of the lateral mass.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objectives To provide a safe transpedicular screw trajectory by measuring the dimensions of the cervical pedicle and evaluating the entrance points and the insertion angles of transpedicular screws.Methods The dimensions of the pedicles(C3-C27) were determined in 30 patients with cervical spinal lesions from CT images.CT images in which each pedicle appeared largest were selected and the following dimensions determined:pedicle inner and outer widths,medial cortical thickness,pedicle axis length and the pedicle transverse angle.Results The mean inner pedicle width ranged from 1.3 to 3.3mm,the mean outer pedicl width ranged from 4.0 to 7.0mm.The smallest pedicle Width was found at C3 among the female subjects for both inner and outer pedicles,The smallest outer pedicle width was 3.2mm,the largtest pedicle width was at C7 in both males(11.1mm) and females(7.4mm).The mean medial cortical thickness ranged from 1.5 to 2.0mm.The pedicle axis length ranged from 29.3 to 33.7mm.The mean pedicle transverse angle ranged from 39.8 to 49.0 degree.Conclusions Axial CT measurements should facilitate transpedicular screw fixation in the cervical spine.We believe that the screw insertion angle should be close to 50 degrees,which is the mean pedicle transverse angle from C3-C6.The entrypoint of the pedicle screw should be located as laterally as possible in the posterior surface of the lateral mass.

Key concepts: Medicine, Transverse plane, Transverse diameter, Anatomy, Lateral mass, Fixation (population genetics), Cervical vertebrae, Computed tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle — Research Paper | ScholarLens