Determination of seventeen elements in stainless steels by laser ablation inductively coupled plasma mass spectrometry

Luo Qian-hu

Open publisher page 1 citations

Abstract

Linear scanning mode ablation was used as sampling strategy,and laser ablation inductively coupled plasma mass spectrometry(LA-ICP-MS)was used for quantitative determination of major,minor and trace elements in stainless steels.The effect of carrier gas in laser ablation cell and its flow,the frequency of laser pulse,the aperture of laser ablation and the output energy density of laser on analytical properties were investigated.The parameters of laser ablation were optimized.The matrix57Fe was used as internal standard to correct the elemental fractionation and sensitivity drifting.The stainless steel crumb certified reference materials for wet analysis were embedded in curing agent such as epoxy resin to prepare assemble-type reference sample as calibration samples.Accordingly,the calibration curve was established.The results showed that,except for P and Pb whose linear correlation coefficient of calibration curve was 0.978 2and 0.967 9respectively,the correlation coefficients of other elements were all higher than 0.99.Detection limit of elements was 0.02-39.71μg/g.The proposed method was applied to the determination of stainless steel certified reference materials,and the results were consistent with the certified values.Except for Al and Pb in sample BS CA 316-4,the relative standard deviations(RSD,n=5)of elements were all less than 10%.Considering the low content of P,its RSD of 10.3%could meet the requirements.

About this research paper

What this paper is about

Linear scanning mode ablation was used as sampling strategy,and laser ablation inductively coupled plasma mass spectrometry(LA-ICP-MS)was used for quantitative determination of major,minor and trace elements in stainless steels.The effect of carrier gas in laser ablation cell and its flow,the frequency of laser pulse,the aperture of laser ablation and the output energy density of laser on analytical properties were investigated.The parameters of laser ablation were optimized.The matrix57Fe was used as internal standard to correct the elemental fractionation and sensitivity drifting.The stainless steel crumb certified reference materials for wet analysis were embedded in curing agent such as epoxy resin to prepare assemble-type reference sample as calibration samples.Accordingly,the calibration curve was established.The results showed that,except for P and Pb whose linear correlation coefficient of calibration curve was 0.978 2and 0.967 9respectively,the correlation coefficients of other elements were all higher than 0.99.Detection limit of elements was 0.02-39.71μg/g.The proposed method was applied to the determination of stainless steel certified reference materials,and the results were consistent with the certified values.Except for Al and Pb in sample BS CA 316-4,the relative standard deviations(RSD,n=5)of elements were all less than 10%.Considering the low content of P,its RSD of 10.3%could meet the requirements.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Linear scanning mode ablation was used as sampling strategy,and laser ablation inductively coupled plasma mass spectrometry(LA-ICP-MS)was used for quantitative determination of major,minor and trace elements in stainless steels.The effect of carrier gas in laser ablation cell and its flow,the frequency of laser pulse,the aperture of laser ablation and the output energy density of laser on analytical properties were investigated.The parameters of laser ablation were optimized.The matrix57Fe was used as internal standard to correct the elemental fractionation and sensitivity drifting.The stainless steel crumb certified reference materials for wet analysis were embedded in curing agent such as epoxy resin to prepare assemble-type reference sample as calibration samples.Accordingly,the calibration curve was established.The results showed that,except for P and Pb whose linear correlation coefficient of calibration curve was 0.978 2and 0.967 9respectively,the correlation coefficients of other elements were all higher than 0.99.Detection limit of elements was 0.02-39.71μg/g.The proposed method was applied to the determination of stainless steel certified reference materials,and the results were consistent with the certified values.Except for Al and Pb in sample BS CA 316-4,the relative standard deviations(RSD,n=5)of elements were all less than 10%.Considering the low content of P,its RSD of 10.3%could meet the requirements.

Key concepts: Calibration curve, Analytical Chemistry (journal), Laser ablation, Certified reference materials, Materials science, Laser, Calibration, Inductively coupled plasma mass spectrometry