Rapid determination of three antiepileptic drugs in serum by high performance liquid chromatography with solid phase extraction method
Sun Zeng
Abstract
Sun Zeng
Abstract
OBJECTIVE To establish a rapid analytical method for the determination of phenobarbital(PB),phenytoin(DPH),carbamazepine(CBZ) in serum by high performance liquid chromatography with solid phase extraction method. METHODS Drugs in serum was extracted with a ccubond SPE C 18 column. The analytical column was Nova-pak C 18 column ( 3.9 mm×150 mm,4 μm). The mobile phase consisted of 0.01 mol·L -1 phosphate buffer solution (pH 3.5):methanol(50∶50).The detective wavelength was 210 nm and the flow rate was 1 mL·min -1, column temperature was 25℃. RESULTS Three drugs were extracted completely, impurities were removed. Three drugs were separated well under the chromatographic condition. The linear range of PB,DPH and CBZ were 5~40、5~40 and 2.5~20 mg·L -1, respectively. The relative recoveries of PB,DPH and CBZ were 100.0%, 99.9% and 100.2%, respectively. The relative standard deviation(RSD) of within day and between day were all less than 5.01%. The method has been used for monitoring serum drug concentration of 55 epileptic patients, the results were compared with liquid-liquid extraction method and there was no difference(P 0.05). CONCLUSION This method is found to be rapid(less than 5 min),simple,accurate, sensitive and more suitable for clinical practical application.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE To establish a rapid analytical method for the determination of phenobarbital(PB),phenytoin(DPH),carbamazepine(CBZ) in serum by high performance liquid chromatography with solid phase extraction method. METHODS Drugs in serum was extracted with a ccubond SPE C 18 column. The analytical column was Nova-pak C 18 column ( 3.9 mm×150 mm,4 μm). The mobile phase consisted of 0.01 mol·L -1 phosphate buffer solution (pH 3.5):methanol(50∶50).The detective wavelength was 210 nm and the flow rate was 1 mL·min -1, column temperature was 25℃. RESULTS Three drugs were extracted completely, impurities were removed. Three drugs were separated well under the chromatographic condition. The linear range of PB,DPH and CBZ were 5~40、5~40 and 2.5~20 mg·L -1, respectively. The relative recoveries of PB,DPH and CBZ were 100.0%, 99.9% and 100.2%, respectively. The relative standard deviation(RSD) of within day and between day were all less than 5.01%. The method has been used for monitoring serum drug concentration of 55 epileptic patients, the results were compared with liquid-liquid extraction method and there was no difference(P 0.05). CONCLUSION This method is found to be rapid(less than 5 min),simple,accurate, sensitive and more suitable for clinical practical application.
Key concepts: Chromatography, Chemistry, Carbamazepine, Extraction (chemistry), Solid phase extraction, Phenobarbital, High-performance liquid chromatography, Phenytoin