2011Yunnan MetallurgyRequires access

Determination of Trace Mercury in Pure Aluminum by Hydride Generation-Atomic Fluorescence Spectrometry

Jingrong Wang

Open publisher page 0 citations

Abstract

Hydride generation-atomic fluorescence spectrometry method is applied to determine trace mercury in pure aluminum,the optimum condition of pure aluminum dissolving is researched too,under the optimized experiment condition,the detection limit of mercury is 0.03 ng/mL,the recovery rate is 96.0%~104.0%,the relative standard deviation is 0.90%.This method is simple,rapid,and has high accuracy,the interference of matrix is small,it can determine mercury in pure aluminum at the range of 0.0000X%~0.00X%,and the result is good.

About this research paper

What this paper is about

Hydride generation-atomic fluorescence spectrometry method is applied to determine trace mercury in pure aluminum,the optimum condition of pure aluminum dissolving is researched too,under the optimized experiment condition,the detection limit of mercury is 0.03 ng/mL,the recovery rate is 96.0%~104.0%,the relative standard deviation is 0.90%.This method is simple,rapid,and has high accuracy,the interference of matrix is small,it can determine mercury in pure aluminum at the range of 0.0000X%~0.00X%,and the result is good.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hydride generation-atomic fluorescence spectrometry method is applied to determine trace mercury in pure aluminum,the optimum condition of pure aluminum dissolving is researched too,under the optimized experiment condition,the detection limit of mercury is 0.03 ng/mL,the recovery rate is 96.0%~104.0%,the relative standard deviation is 0.90%.This method is simple,rapid,and has high accuracy,the interference of matrix is small,it can determine mercury in pure aluminum at the range of 0.0000X%~0.00X%,and the result is good.

Key concepts: Mercury (programming language), Hydride, Detection limit, Relative standard deviation, Chemistry, Analytical Chemistry (journal), Aluminium, Dissolution

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Mercury in Pure Aluminum by Hydride Generation-Atomic Fluorescence Spectrometry — Research Paper | ScholarLens