2012Metallurgical AnalysisRequires access

Simultaneous determination of trace arsenic,antimony,selenium and tellurium in pure copper by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry

Yan Zhang

Open publisher page 0 citations

Abstract

After samples were dissolved by nitric acid,lanthanum hydroxide was used to co-precipitate As,Sb,Se,and Te for separation with copper substrate in ammonia medium,and As,Sb,Se,and Te in pure copper were simultaneously determined by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry.Hydride generation conditions and operation parameters for simultaneous determination of four elements were optimized.The results showed that,under optimal conditions,the detection limit of As,Sb,Se and Te were 0.04,0.05,0.04 and 0.03 ng/mL respectively,and relative standard deviation(RSD,n=7) were 0.97%,0.77%,0.57 % and 1.0% respectively for 20 ng/mL As,Sb and 10 ng/mL Se,Te mixed standard solution.This method was applied to simultaneous determination of As,Sb,Se,and Te in actual samples.The determination results had no significant difference with those obtained by national standard method,and the relative standard deviation was 7.0% with recoveries of 94%-105%.

About this research paper

What this paper is about

After samples were dissolved by nitric acid,lanthanum hydroxide was used to co-precipitate As,Sb,Se,and Te for separation with copper substrate in ammonia medium,and As,Sb,Se,and Te in pure copper were simultaneously determined by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry.Hydride generation conditions and operation parameters for simultaneous determination of four elements were optimized.The results showed that,under optimal conditions,the detection limit of As,Sb,Se and Te were 0.04,0.05,0.04 and 0.03 ng/mL respectively,and relative standard deviation(RSD,n=7) were 0.97%,0.77%,0.57 % and 1.0% respectively for 20 ng/mL As,Sb and 10 ng/mL Se,Te mixed standard solution.This method was applied to simultaneous determination of As,Sb,Se,and Te in actual samples.The determination results had no significant difference with those obtained by national standard method,and the relative standard deviation was 7.0% with recoveries of 94%-105%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

After samples were dissolved by nitric acid,lanthanum hydroxide was used to co-precipitate As,Sb,Se,and Te for separation with copper substrate in ammonia medium,and As,Sb,Se,and Te in pure copper were simultaneously determined by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry.Hydride generation conditions and operation parameters for simultaneous determination of four elements were optimized.The results showed that,under optimal conditions,the detection limit of As,Sb,Se and Te were 0.04,0.05,0.04 and 0.03 ng/mL respectively,and relative standard deviation(RSD,n=7) were 0.97%,0.77%,0.57 % and 1.0% respectively for 20 ng/mL As,Sb and 10 ng/mL Se,Te mixed standard solution.This method was applied to simultaneous determination of As,Sb,Se,and Te in actual samples.The determination results had no significant difference with those obtained by national standard method,and the relative standard deviation was 7.0% with recoveries of 94%-105%.

Key concepts: Hydride, Antimony, Detection limit, Chemistry, Arsenic, Tellurium, Selenium, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of trace arsenic,antimony,selenium and tellurium in pure copper by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry — Research Paper | ScholarLens