2006Technology & Development of Chemical IndustryRequires access

Determination of Trace Mercury in Drinking Mineral Water by Hydride Generation Atomic Fluorescence Spectrometry

Cheng Tong-huan

Open publisher page 0 citations

Abstract

A method was established for the determination of the trace mercury in drinking mineral water.The effect of the sewage sample treated with aqua regia(1+1),acid medium and reducing agent on the determination of the mercury were studied.Under the optimum conditions,the linear range of determination was 0~2.0 ng·mL~(-1),the detection limit was 0.0003 μg·L~(-1).The average recovery was between 95%~104%.The method was accurate,rapid and convenient with satisfactory results.

About this research paper

What this paper is about

A method was established for the determination of the trace mercury in drinking mineral water.The effect of the sewage sample treated with aqua regia(1+1),acid medium and reducing agent on the determination of the mercury were studied.Under the optimum conditions,the linear range of determination was 0~2.0 ng·mL~(-1),the detection limit was 0.0003 μg·L~(-1).The average recovery was between 95%~104%.The method was accurate,rapid and convenient with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was established for the determination of the trace mercury in drinking mineral water.The effect of the sewage sample treated with aqua regia(1+1),acid medium and reducing agent on the determination of the mercury were studied.Under the optimum conditions,the linear range of determination was 0~2.0 ng·mL~(-1),the detection limit was 0.0003 μg·L~(-1).The average recovery was between 95%~104%.The method was accurate,rapid and convenient with satisfactory results.

Key concepts: Mercury (programming language), Aqua regia, Detection limit, Chemistry, Hydride, Linear range, Environmental chemistry, Mineral water

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Mercury in Drinking Mineral Water by Hydride Generation Atomic Fluorescence Spectrometry — Research Paper | ScholarLens