Simultaneous Determination of Two Kinds of Agricultural Chemicals in Soil by a New Amino Acid-derived Stationary Phase for HPLC
Zhihua Deng, Liu Yungen, Xia HongYun, Yawei Cui, Qibin Liang
Abstract
Zhihua Deng, Liu Yungen, Xia HongYun, Yawei Cui, Qibin Liang
Abstract
By N-Benzyloxycarbonyl-L-Phenylglycine-L-Phenylglycine-derived Silica Gel Stationary Phase(BCPGPGSP),a simple and reliable positive-phase high performance liquid chromatographic (HPLC) method for the routine analysis of cypermethrin and fenvalerate in soil has been established. HPLC determination for the sample was performed in a BCPGPGSP column and detected at 254nm. Using a mixed solvent of hexane-dichloromethane(80~10,V/V)as the mobile phase,and the flow rate was 1.0mL/min.The method was proved to be liner in the ranges of 0~2.0mg/L for cypermethrin and fenvalerate. The relative standard deviations of inter-assay (n=4)were 5.70% for cypermethrin analysis and 5.5% for fenvalerate analysis. The recoveries of cypermethrin and fenvalerate were 81.0%~96% and 88.0%~96.7% respectively. The method has been successfully applied to the simultaneous determination of the cypermethrin and fenvalerate in soil.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
By N-Benzyloxycarbonyl-L-Phenylglycine-L-Phenylglycine-derived Silica Gel Stationary Phase(BCPGPGSP),a simple and reliable positive-phase high performance liquid chromatographic (HPLC) method for the routine analysis of cypermethrin and fenvalerate in soil has been established. HPLC determination for the sample was performed in a BCPGPGSP column and detected at 254nm. Using a mixed solvent of hexane-dichloromethane(80~10,V/V)as the mobile phase,and the flow rate was 1.0mL/min.The method was proved to be liner in the ranges of 0~2.0mg/L for cypermethrin and fenvalerate. The relative standard deviations of inter-assay (n=4)were 5.70% for cypermethrin analysis and 5.5% for fenvalerate analysis. The recoveries of cypermethrin and fenvalerate were 81.0%~96% and 88.0%~96.7% respectively. The method has been successfully applied to the simultaneous determination of the cypermethrin and fenvalerate in soil.
Key concepts: Fenvalerate, Cypermethrin, Chromatography, High-performance liquid chromatography, Chemistry, Dichloromethane, Solvent, Hexane