2006PubMedRequires access

[The effect of cervical gas insufflation on metabolic and hemodynamic during endoscopic neck surgery].

Zheng Zhou, Ming Xie, Jiadong Wang

Open publisher page 1 citations

Abstract

OBJECTIVE: Carbon dioxide and helium were insufflated into the neck of rabbits to investigate the effect of different levels of insufflation pressure and duration on metabolic and hemodynamic changes. METHOD: Fifteen New Zealand rabbits were randomly divided into 5 groups: 5 mmHg CO2, 10 mmHg CO2, 15 mmHg CO2, 15 mmHg He and 0 mmHg. Arterial partial pressure of CO2 (PaCO2), pH, heart rate (HR), mean arterial pressure (MAP) and central venous pressure (CVP) were measured at baseline, 45 min and 90 min after gas insufflation and 30 min after desufflation. RESULT: Insufflation of CO2 at 5 mmHg had not any significant effect on the parameters. PaCO2 increased significantly 45 min and 90 min after CO2 insufflation at 10 mmHg (P < 0.05). Marked changes in PaCO2, pH and CVP occurred 45 min and 90 min after CO2 insufflation at 15 mmHg (P < 0.05), and the parameters did not return to baseline 30 min after desufflation. In animals receiving He insufflation at 15 mmHg, CVP increased significantly after 90 min (P < 0.05), and the parameters returned to baseline 30 min after desufflation. Animals receiving He insufflation did not experience hypercapnia. No significant changes in HR and MAP occurred in all animals. CONCLUSION: Carbon dioxide insufflation for endoscopic neck surgery is safe below 10 mmHg. When higher pressure is required, the level lower than 15 mmHg is recommended and the insufflation duration should be limited. The use of He should be careful due to the low solubility.

About this research paper

What this paper is about

OBJECTIVE: Carbon dioxide and helium were insufflated into the neck of rabbits to investigate the effect of different levels of insufflation pressure and duration on metabolic and hemodynamic changes. METHOD: Fifteen New Zealand rabbits were randomly divided into 5 groups: 5 mmHg CO2, 10 mmHg CO2, 15 mmHg CO2, 15 mmHg He and 0 mmHg. Arterial partial pressure of CO2 (PaCO2), pH, heart rate (HR), mean arterial pressure (MAP) and central venous pressure (CVP) were measured at baseline, 45 min and 90 min after gas insufflation and 30 min after desufflation. RESULT: Insufflation of CO2 at 5 mmHg had not any significant effect on the parameters. PaCO2 increased significantly 45 min and 90 min after CO2 insufflation at 10 mmHg (P < 0.05). Marked changes in PaCO2, pH and CVP occurred 45 min and 90 min after CO2 insufflation at 15 mmHg (P < 0.05), and the parameters did not return to baseline 30 min after desufflation. In animals receiving He insufflation at 15 mmHg, CVP increased significantly after 90 min (P < 0.05), and the parameters returned to baseline 30 min after desufflation. Animals receiving He insufflation did not experience hypercapnia. No significant changes in HR and MAP occurred in all animals. CONCLUSION: Carbon dioxide insufflation for endoscopic neck surgery is safe below 10 mmHg. When higher pressure is required, the level lower than 15 mmHg is recommended and the insufflation duration should be limited. The use of He should be careful due to the low solubility.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Carbon dioxide and helium were insufflated into the neck of rabbits to investigate the effect of different levels of insufflation pressure and duration on metabolic and hemodynamic changes. METHOD: Fifteen New Zealand rabbits were randomly divided into 5 groups: 5 mmHg CO2, 10 mmHg CO2, 15 mmHg CO2, 15 mmHg He and 0 mmHg. Arterial partial pressure of CO2 (PaCO2), pH, heart rate (HR), mean arterial pressure (MAP) and central venous pressure (CVP) were measured at baseline, 45 min and 90 min after gas insufflation and 30 min after desufflation. RESULT: Insufflation of CO2 at 5 mmHg had not any significant effect on the parameters. PaCO2 increased significantly 45 min and 90 min after CO2 insufflation at 10 mmHg (P < 0.05). Marked changes in PaCO2, pH and CVP occurred 45 min and 90 min after CO2 insufflation at 15 mmHg (P < 0.05), and the parameters did not return to baseline 30 min after desufflation. In animals receiving He insufflation at 15 mmHg, CVP increased significantly after 90 min (P < 0.05), and the parameters returned to baseline 30 min after desufflation. Animals receiving He insufflation did not experience hypercapnia. No significant changes in HR and MAP occurred in all animals. CONCLUSION: Carbon dioxide insufflation for endoscopic neck surgery is safe below 10 mmHg. When higher pressure is required, the level lower than 15 mmHg is recommended and the insufflation duration should be limited. The use of He should be careful due to the low solubility.

Key concepts: Insufflation, Hypercapnia, Anesthesia, Medicine, Hemodynamics, Mean arterial pressure, Blood pressure, Heart rate

Related papers

Back to paper searchBrowse research topicsOriginal source
[The effect of cervical gas insufflation on metabolic and hemodynamic during endoscopic neck surgery]. — Research Paper | ScholarLens