STUDIES ON THE FEASIBILITY OF DIRECT MEASUREMENT OF N LOSSES AS N_2 AND N_2O PRODUCED BY DENITRIFICATION WITH ~(15)N TRACER TECHNIQUE AND MASS SPECTROMETER
Ni Wu
Abstract
Ni Wu
Abstract
With 15 N tracer technique, mass spectrometer and a self\|designed installation including sample entrance, reduced Cu tube, high\|efficiency O\-2 trap, liquid N\-2 cold trap, a method for direct determination of N losses as N\-2 and N\-2O produced by denitrification is set up.The average of 15 N natural abundance of atmospheric samples determined is 0\^3659%(the theoretical value is 0\^3660%) with C.V.% of 0\^09% and an average of absolute error of 0\^0002%, which is up to the error standard of the mass spectrometer used. C.V.% of measurement of 15 N abundance in different gas samples and in the substrate NO\+\+-\-\-3 undergoing denitrification are 0\^03%~1 08% and 1\^22%~5\^21%,respectively,indicating that the pretreating installation is highly efficient for elimination of O\-2, CO\-2 and H\-2O in gas samples, and the method is feasible for direct measurement of 15 N losses as N\-2 and N\-2O. As the calculation of 15 N losses is based on atom excess % of 15 N( 15 N abundance of gas sample minus 15 N natural abundance of atmospheric N\-2), C.V.% of determination of 15 N losses is probably larger than 5% if atom excess % of 15 N in gas samples is smaller than 0\^014%. It is suggested that the 15 N abundance higher than 0\^380% in gas samples be suitable.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
With 15 N tracer technique, mass spectrometer and a self\|designed installation including sample entrance, reduced Cu tube, high\|efficiency O\-2 trap, liquid N\-2 cold trap, a method for direct determination of N losses as N\-2 and N\-2O produced by denitrification is set up.The average of 15 N natural abundance of atmospheric samples determined is 0\^3659%(the theoretical value is 0\^3660%) with C.V.% of 0\^09% and an average of absolute error of 0\^0002%, which is up to the error standard of the mass spectrometer used. C.V.% of measurement of 15 N abundance in different gas samples and in the substrate NO\+\+-\-\-3 undergoing denitrification are 0\^03%~1 08% and 1\^22%~5\^21%,respectively,indicating that the pretreating installation is highly efficient for elimination of O\-2, CO\-2 and H\-2O in gas samples, and the method is feasible for direct measurement of 15 N losses as N\-2 and N\-2O. As the calculation of 15 N losses is based on atom excess % of 15 N( 15 N abundance of gas sample minus 15 N natural abundance of atmospheric N\-2), C.V.% of determination of 15 N losses is probably larger than 5% if atom excess % of 15 N in gas samples is smaller than 0\^014%. It is suggested that the 15 N abundance higher than 0\^380% in gas samples be suitable.
Key concepts: Analytical Chemistry (journal), Mass spectrometry, Chemistry, Cold trap, TRACER, Denitrification, Abundance (ecology), Natural abundance